ISL6595DRZ Intersil, ISL6595DRZ Datasheet - Page 21

IC DIGITL MULTIPHASE CTRLR 48QFN

ISL6595DRZ

Manufacturer Part Number
ISL6595DRZ
Description
IC DIGITL MULTIPHASE CTRLR 48QFN
Manufacturer
Intersil
Datasheet

Specifications of ISL6595DRZ

Applications
Digital Multiphase Controller
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
100mA
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-VQFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
oovp_limit [5:0]
fault1_mask[12:0]
fault2_mask[12:0]
shutdown_mask[10:0]
ch_mask[6:1]
REGISTER
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
For information regarding Intersil Corporation and its products, see www.intersil.com
Output overvoltage protect threshold. Tracking VID over
voltage threshold.
FAULT1, FAULT2 pin output masks. Inputs are enabled for
reporting when set to logic 1. If multiple inputs are selected,
output is “OR” of selected input signals.
Shutdown control mask. Inputs are enabled for shutdown
when set to logic 1. If multiple inputs are selected, output is
“OR” of selected input signals.
10 =
Channel mask. Selects number of active phases. Phases
must be selected in sequential order.
000011 = 2-phase operation
000111 = 3-phase operation
001111 = 4-phase operation
011111 = 5-phase operation
111111 = 6-phase operation
15 = Current ADC over range
14 = Load current monitor
13 = Average total current fault
12 = NVM fault
10 = IUVP
11 = Internal bus fault
11=
8 =
0 =
9 = OUVP
8 = OOVP
7 = VR_HOT alert
6 = VR_FAN alert
5 = External (thermistor) temp alert
4 = External (thermistor) temp shutdown
3 = Internal (PTAT) temp alert
2 = Internal (PTAT) temp shutdown
1 = MHz controller fault
0 = Calibration fault
9 = Total current fault during soft-start
7 = Individual phase current fault during soft-start
6 = Current ADC over range fault
5 = IUVP
4 = OUVP
3 = OOVP
2 = Thermistor temp shutdown
1 = PTAT temp shutdown 0 = Calibration fault
21
Averal total current fault
Total current fault during active regulation
Individual phase current fault during active regulation
Calibration fault
DESCRIPTION
TABLE 4. KEY REGISTERS (Continued)
ISL6595
FORMAT
R/W
R/W
R/W
0.0mV
MIN
RANGE
787.5mV
MAX
RESOLUTION
December 4, 2008
12.5mV
FN9192.2

Related parts for ISL6595DRZ