Specifications of ADT7460ARQZ

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 120°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 120°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (3-Wire)
Maximum Operating Temperature
+ 120 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7460ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7460ARQZ-REEL
Manufacturer:
ST
Quantity:
16
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
1. These registers become read−only when the Configuration Register 1 lock bit is set to 1. Further attempts to write to the is register have no effect.
Table 52. PWM Configuration Registers (Power−On Default = 0x62)
Table 53. PWM Configuration Register Bits
Table 54. Temp T
Bit No.
<2:0>
<7:5>
<3>
<4>
Register Address
Register Address
0x5C
0x5D
0x5E
0x5F
0x60
0x61
Mnemonic
SLOW
BHVR
SPIN
INV
RANGE
/PWM Frequency Registers (Power−On Default = 0xC4)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
PWM1 configuration.
PWM2 configuration.
PWM3 configuration.
These bits control the startup timeout for PWMx. The PWM output stays high until two valid
TACH rising edges are seen from the fan. If there is not a valid TACH signal during the fan
TACH measurement directly after the fan startup timeout period, the TACH measurement reads
0xFFFF and Status Register 2 reflects the fan fault. If the TACH minimum high and low byte
contains 0xFFFF or 0x0000, the Status Register 2 bit is not set, even if the fan has not started.
SLOW = 1 makes the ramp rates for acoustic enhancement four times longer.
This bit inverts the PWM output. The default is 0, which corresponds to a logic high output for
100% duty cycle. Setting this bit to 1 inverts the PWM output, so 100% duty cycle corresponds
to a logic low output.
These bits assign each fan to a particular temperature sensor for localized cooling.
Remote 1 T
Local Temp T
Remote 2 T
000 = No startup timeout
001 = 100 ms
010 = 250 ms (default)
011 = 400 ms
100 = 667 ms
101 = 1 s
110 = 2 s
111 = 4 s
000 = Remote 1 temperature controls PWMx (automatic fan control mode).
001 = Local temperature controls PWMx (automatic fan control mode).
010 = Remote 2 temperature controls PWMx (automatic fan control mode).
011 = PWMx runs full speed (default).
100 = PWMx is disabled.
101 = Fastest speed calculated by Local and Remote 2 Temperature Control PWMx.
110 = Fastest speed calculated by all three Temperature Channels Control PWMx.
111 = Manual mode. PWM duty cycle registers (Reg. 0x30–0x32) become writable.
RANGE
RANGE
RANGE
http://onsemi.com
/PWM1 frequency.
/PWM3 frequency.
/PWM2 frequency.
ADT7460