TS821ILT STMicroelectronics, TS821ILT Datasheet - Page 2

IC VREF 1.225V SHUNT MPWR SOT-23

TS821ILT

Manufacturer Part Number
TS821ILT
Description
IC VREF 1.225V SHUNT MPWR SOT-23
Manufacturer
STMicroelectronics
Datasheet

Specifications of TS821ILT

Reference Type
Shunt
Voltage - Output
1.225V
Tolerance
±2%
Temperature Coefficient
120ppm/°C
Number Of Channels
1
Current - Cathode
40µA
Current - Output
12mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
SOT-23-3, TO-236-3, Micro3™, SSD3, SST3
Product
Voltage References
Topology
Shunt References
Output Voltage
1.225 V
Initial Accuracy
2 %
Average Temperature Coefficient (typ)
120 PPM / C
Shunt Current (max)
12 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Shunt Current (min)
0.045 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Current - Quiescent
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TS821ILT
Manufacturer:
ST
Quantity:
63 000
Part Number:
TS821ILT
Manufacturer:
ST
Quantity:
20 000
Absolute maximum ratings and operating conditions
1
2/9
Absolute maximum ratings and operating conditions
Table 1.
1. P
2. Human body model: 100pF discharged through a 1.5kΩ resistor between two pins of the device, done for
3. Machine model: a 200pF cap is charged to the specified voltage, then discharged directly between two pins
Table 2.
Symbol
Symbol
ESD
T
T
I
T
all couples of pin combinations with other pins floating.
of the device with no external series resistor (internal resistor < 5Ω), done for all couples of pin
combinations with other pins floating.
I
max
P
oper
lead
min
I
I
stg
d
k
f
d
is calculated with T
Reverse breakdown current
Forward current
Power dissipation
Storage temperature
Human body model (HBM)
Machine model (MM)
Lead temperature (soldering, 10 seconds)
Minimum operating current
Maximum operating current
Operating free air temperature range
Absolute maximum ratings (AMR)
Operating conditions
amb
= 25°C and T
(1)
SOT23-3
(3)
Parameter
Parameter
(2)
j
= 150°C and R
thja
= 340°C/W for the SOT23-3L package.
-65 to +150
-40 to +85
Value
Value
360
200
260
20
10
45
12
2
TS821
Unit
Unit
mW
mA
mA
mA
kV
°C
μA
°C
°C
V