Specifications of ADUM3440CRWZ

Propagation Delay
36ns
Inputs - Side 1/side 2
4/0
Number Of Channels
4
Isolation Rating
2500Vrms
Voltage - Supply
3 V ~ 5.5 V
Data Rate
150Mbps
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
4
Supply Current
120mA
Supply Voltage Range
3V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
105C
Package Type
SOIC W
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM3440CRWZ
Manufacturer:
AD
Quantity:
301
Part Number:
ADUM3440CRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUM3440CRWZ-RL
Manufacturer:
AD
Quantity:
3 125
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval.
Table 7.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
Highest Allowable Overvoltage
Safety-Limiting Values
Insulation Resistance at T
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting Values
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
After Environmental Tests Subgroup 1
Case Temperature
Side 1 Current
Side 2 Current
After Input and/or Safety Test
Subgroup 2 and Subgroup 3
350
300
250
200
150
100
50
0
0
with Case Temperature per DIN V VDE V 0884-10
50
CASE TEMPERATURE (°C)
SIDE #1
S
SIDE #2
100
150
Conditions
V
partial discharge < 5 pC
V
Transient overvoltage, t
Maximum value allowed in the event of a failure
(see Figure 4)
V
V
IORM
IORM
IORM
IO
= 500 V
× 1.875 = V
× 1.6 = V
× 1.2 = V
200
PR
PR
Rev. C | Page 11 of 24
PR
, t
, t
, 100% production test, t
m
m
= 60 sec, partial discharge < 5 pC
= 60 sec, partial discharge < 5 pC
TR
= 10 seconds
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter
Operating Temperature Range, T
Supply Voltage Range, V
Input Signal Rise and Fall Time
1
All voltages are relative to their respective ground. See the
and Magnetic Field Immunity
magnetic fields.
ADuM3440/ADuM3441/ADuM3442
m
= 1 sec,
section for information on immunity to external
DD1
Symbol
V
V
V
V
T
I
I
R
, V
S1
S2
S
IORM
PR
PR
TR
S
DD2
1
A
Characteristic
I to IV
I to III
I to II
40/105/21
2
560
1050
896
672
4000
150
265
335
>10
9
Rating
−40°C to +105°C
3.0 V to 5.5 V
1.0 ms
DC Correctness
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Ω