ADUM3440CRWZ Analog Devices Inc, ADUM3440CRWZ Datasheet - Page 20

no-image

ADUM3440CRWZ

Manufacturer Part Number
ADUM3440CRWZ
Description
IC DIGITAL ISOLATOR 4INP 16SOIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM3440CRWZ

Propagation Delay
36ns
Inputs - Side 1/side 2
4/0
Number Of Channels
4
Isolation Rating
2500Vrms
Voltage - Supply
3 V ~ 5.5 V
Data Rate
150Mbps
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
4
Supply Current
120mA
Supply Voltage Range
3V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
105C
Package Type
SOIC W
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM3440CRWZ
Manufacturer:
AD
Quantity:
301
Part Number:
ADUM3440CRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUM3440CRWZ-RL
Manufacturer:
AD
Quantity:
3 125
ADuM3440/ADuM3441/ADuM3442
INSULATION LIFETIME
All insulation structures eventually break down when subjected
to voltage stress over a sufficiently long period. The rate of
insulation degradation is dependent on the characteristics of
the voltage waveform applied across the insulation. In addition
to the testing performed by the regulatory agencies, Analog
Devices carries out an extensive set of evaluations to determine
the lifetime of the insulation structure within the ADuM344x.
Analog Devices performs accelerated life testing using voltage levels
higher than the rated continuous working voltage. Acceleration
factors for several operating conditions are determined. These
factors allow calculation of the time to failure at the actual working
voltage. The values shown in Figure 20 summarize the peak voltage
for 50 years of service life for a bipolar ac operating condition,
and the maximum CSA/VDE approved working voltages. In
many cases, the approved working voltage is higher than the
50-year service life voltage. Operation at these high working
voltages can lead to shortened insulation life in some cases.
The insulation lifetime of the ADuM344x depends on the
voltage waveform type imposed across the isolation barrier.
The iCoupler insulation structure degrades at different rates
depending on whether the waveform is bipolar ac, unipolar ac,
or dc. Figure 20, Figure 21, and Figure 22 illustrate these
different isolation voltage waveforms.
Bipolar ac voltage is the most stringent environment. The goal
of a 50-year operating lifetime under the ac bipolar condition
determines the maximum working voltage recommended by
Analog Devices.
Rev. C | Page 20 of 24
In the case of unipolar ac or dc voltage, the stress on the insulation
is significantly lower, which allows operation at higher working
voltages while still achieving a 50-year service life. The working
voltages listed in Table 10 can be applied while maintaining the
50-year minimum lifetime provided the voltage conforms to
either the unipolar ac or dc voltage cases. Any cross insulation
voltage waveform that does not conform to Figure 21 or Figure 22
should be treated as a bipolar ac waveform and its peak voltage
should be limited to the 50-year lifetime voltage value listed in
Table 10.
Note that the voltage presented in Figure 21 is shown as sinusoidal
for illustration purposes only. It is meant to represent any voltage
waveform varying between 0 V and some limiting value. The
limiting value can be positive or negative, but the voltage
cannot cross 0 V.
RATED PEAK VOLTAGE
RATED PEAK VOLTAGE
RATED PEAK VOLTAGE
0V
0V
0V
Figure 21. Unipolar AC Waveform
Figure 20. Bipolar AC Waveform
Figure 22. DC Waveform