ADUM5242ARZ Analog Devices Inc, ADUM5242ARZ Datasheet - Page 5

IC ISOLATOR 2CH W/CONV 8-SOIC

ADUM5242ARZ

Manufacturer Part Number
ADUM5242ARZ
Description
IC ISOLATOR 2CH W/CONV 8-SOIC
Manufacturer
Analog Devices Inc
Series
IsoPower®, iCoupler®r
Datasheet

Specifications of ADUM5242ARZ

Propagation Delay
70ns
Inputs - Side 1/side 2
0/2
Number Of Channels
2
Isolation Rating
2500Vrms
Voltage - Supply
3.35V, 4.1V, 5V
Data Rate
1Mbps
Output Type
Logic
Package / Case
8-SOIC (3.9mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
2
Supply Current
140mA
Supply Voltage Range
2.7V To 4V, 4.5V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
8
Operating Temperature Range
-40°C To
Package
8SOIC N
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
105C
Package Type
SOIC N
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM5242ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUM5242ARZ-RL7
Manufacturer:
ADI
Quantity:
6 000
Part Number:
ADUM5242ARZ-RL7CT-ND
Manufacturer:
ADI
Quantity:
218
PACKAGE CHARACTERISTICS
Table 2.
Parameter
Resistance (Input-to-Output)
Capacitance (Input-to-Output)
Input Capacitance
IC Junction-to-Air Thermal Resistance
REGULATORY INFORMATION
The ADuM524x are approved by the organizations listed in Table 3. Refer to Table 8 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific crossisolation waveforms and insulation levels.
Table 3.
UL
Recognized under 1577
Component Recognition Program
Single/basic insulation, 2500 V rms
isolation rating
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 4.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Maximum Working Voltage Compatible with
In accordance with UL 1577, each ADuM524x is proof-tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 μA).
In accordance with DIN V VDE V 0884-10, each ADuM524x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
50-Year Service Life
1
CSA
Approved under CSA Component
Acceptance Notice #5A
Basic insulation per CSA 60950-1-03
and IEC 60950-1, 400 V rms (566 V peak)
maximum working voltage
File 205078
Symbol
R
C
C
θ
I-O
JA
I-O
I
Symbol
L(I01)
L(I02)
CTI
V
IORM
Rev. A | Page 5 of 16
Value
2500
4.90 min
4.01 min
0.017 min
>175
IIIa
425
Min
Typ
10
1.0
4.0
80
12
Unit
V rms
mm
mm
mm
V
V peak
ADuM5240/ADuM5241/ADuM5242
Max
VDE
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
Reinforced insulation, 560 V peak
File 2471900-4880-0001
Conditions
1-minute duration
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Continuous peak voltage across the
isolation barrier
Unit
Ω
pF
pF
°C/W
Test Conditions
f = 1 MHz
2

Related parts for ADUM5242ARZ