HCPL-2531#520 Avago Technologies US Inc., HCPL-2531#520 Datasheet - Page 8

OPTOCOUPLER 2CH 1MBS UL 8-SMD

HCPL-2531#520

Manufacturer Part Number
HCPL-2531#520
Description
OPTOCOUPLER 2CH 1MBS UL 8-SMD
Manufacturer
Avago Technologies US Inc.
Datasheets

Specifications of HCPL-2531#520

Input Type
DC
Package / Case
8-SMD Gull Wing
Voltage - Isolation
5000Vrms
Number Of Channels
2, Unidirectional
Current - Output / Channel
8mA
Data Rate
1MBd
Propagation Delay High - Low @ If
200ns @ 16mA
Current - Dc Forward (if)
25mA
Output Type
Open Collector
Mounting Type
Surface Mount, Gull Wing
Isolation Voltage
3750 Vrms
Output Device
Phototransistor
Configuration
2 Channel
Current Transfer Ratio
50 %
Maximum Baud Rate
1 MBps
Maximum Forward Diode Voltage
1.8 V
Maximum Reverse Diode Voltage
5 V
Maximum Input Diode Current
25 mA
Maximum Power Dissipation
100 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
HCPL-2531#520HCPL-2531
Manufacturer:
AVAGO
Quantity:
40 000
Company:
Part Number:
HCPL-2531#520HCPL-2531
Manufacturer:
AGILENT
Quantity:
20 000
Company:
Part Number:
HCPL-2531#520HCPL-2531#300E
Manufacturer:
AVAGO
Quantity:
10 000
Company:
Part Number:
HCPL-2531#520HCPL-2531-000E
Manufacturer:
PANASONIC
Quantity:
2 000
Company:
Part Number:
HCPL-2531#520HCPL-2531-000E
Manufacturer:
AVAGO
Quantity:
40 000
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (OPTION 060 ONLY)
Insulation Resistance at T
8
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCNW4502/3 ONLY)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
V
Partial Discharge < 5 pC
V
t
(Maximum values allowed in the event of a failure,
also see Figure 9, Thermal Derating curve.)
V
V
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
Partial Discharge < 5 pC
t
(Maximum values allowed in the event of a failure,
also see Figure 9, Thermal Derating curve.)
m
m
IORM
IORM
IORM
IORM
Case Temperature
Input Current
Output Power
= 60 sec, Partial Discharge < 5 pC
Case Temperature
Input Current
Output Power
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
x 1.875 = V
x 1.5 = V
PR
PR
, Type and sample test,
, Type and sample test,
PR
PR
, 100% Production Test with t
, 100% Production Test with t
S
, V
ini
ini
S
IO
, V
= 10 sec)
= 10 sec)
= 500 V
IO
= 500 V
Description
m
m
= 1 sec,
= 1 sec,
Symbol
V
V
V
V
T
I
P
R
S,INPUT
IORM
S
S,OUTPUT
PR
PR
IOTM
S
HCPL-4502/4503
I-IV
I-III
55/100/21
2
630
1181
945
6000
175
230
600
≥10
Symbol
V
V
V
V
T
I
P
R
S,INPUT
IORM
S
S,OUTPUT
PR
PR
IOTM
S
9
Characteristic
HCPL-0452/0453
I-III
55/100/21
2
560
1050
840
4000
175
150
600
≥10
Characteristic
I-IV
I-III
55/85/21
2
1414
2652
2121
8000
150
400
700
≥ 10
9
9
mA
Units
V
V
V
V
°C
mW
Ω
Units
V
V
V
V
°C
mA
mW
Ω
peak
peak
peak
peak
peak
peak
peak
peak

Related parts for HCPL-2531#520