KP-FSD2 Panduit Corp, KP-FSD2 Datasheet - Page 751

KIT FERRULE INS DIN AWG22-14

KP-FSD2

Manufacturer Part Number
KP-FSD2
Description
KIT FERRULE INS DIN AWG22-14
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule Kitr
Datasheet

Specifications of KP-FSD2

Kit Type
Ferrule - Wire End
Values
400 pcs - Assorted Insulated 22 ~ 14 AWG Ferrules
Where Used
To terminate stranded wire for insertion into terminal blocks
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use with Copper Code Conductors
Type ML-T
• Made from high strength, electrolytic copper to provide premium
• Tin-plated to inhibit corrosion
• Compact design saves space
• Wide wire range-taking capability minimizes inventory requirements
For Use with Copper Code Conductors
Type PNL
• Cast from high strength corrosion resistant copper alloy to provide
• Compact design saves space
• Wide wire range-taking capability minimizes inventory requirements
• Inspection window to visually assure full conductor insertion
electrical and mechanical performance
premium electrical and mechanical performance
One-Hole, Straight Tongue, Tin-Plated, Barrel Post Lug
One-Hole, Straight Tongue Lug
Part Number
PNL-4-C
PNL-1/0-L
PNL-250-Q
PNL-500-3
PNL-1000-3
Part Number
ML8T-CY
ML4T-CY
ML1/0T-LY
ML250T-QY
**Uses slotted head set screw.
**Uses slotted head set screw.
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
Copper Conductor
#6 SOL – 250 kcmil
#4 SOL – 500 kcmil
Copper Conductor
#14 SOL – 1/0 STR
#6 STR – 250 kcmil
#14 SOL – #4 STR
#14 SOL – #8 STR
#14 SOL – #4 STR
#8 SOL – 1/0 STR
500 kcmil – 1000
ELECTRICAL SOLUTIONS
Size Range
Size Range
kcmil
• Inspection window to visually assure full conductor insertion
• Plated steel set screw provides high strength, durable electrical
• Flat bottom allows for complete contact with mounting surface
• UL Listed for use up to 600 V and temperature rated 90°C
• Plated steel set screw provides high strength, durable electrical
• Flat bottom allows for complete contact with mounting surface
• UL Listed and CSA Certified for use up to 600 V and UL
W
W
contact between conductor and connector
contact between conductor and connector
temperature rated 90°C
Stud Hole
Stud Hole
Size
5/16
Size
3/16
5/16
(In.)
(In.)
1/4
3/8
1/2
1/2
1/4
3/8
L
Hex Key
Hex Key
L
Size
5/16
Size
(In.)
(In.)
1/4
3/8
1/2
1/4
1/4
**
**
**
T
1.25
1.59
1.97
3.00
3.88
0.81
1.11
1.58
1.94
L
L
T
0.53
0.73
0.94
1.38
1.75
0.38
0.54
0.73
0.94
P
Figure Dimensions
Figure Dimensions
W
W
P
(In.)
0.56
0.78
1.05
1.47
2.00
(In.)
0.42
0.55
0.79
1.06
H
H
0.14
0.14
0.13
0.25
0.38
0.08
0.09
0.09
0.12
T
T
H
0.66
0.85
1.00
1.63
2.13
0.48
0.63
0.80
1.00
P
P
H
Pkg.
Pkg.
Std.
Qty.
Std.
Qty.
100
100
100
50
25
50
25
3
3
D2.129
Management
Identification
Accessories
Connectors
Connectors
Grounding
Pre-Printed
& Write-On
Protection
Permanent
Solutions
Cable Ties
Terminals
Lockout/
Overview
Steel Ties
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
Surface
Markers
Tagout
System
Wiring
Labels
Power
Cable
Cable
Index
Duct
E5.
B1.
B2.
B3.
D1.
D2.
D3.
C1.
C2.
C3.
C4.
E1.
E2.
E3.
E4.
A.
F.