SU3000XLNAFTA Tripp Lite, SU3000XLNAFTA Datasheet

no-image

SU3000XLNAFTA

Manufacturer Part Number
SU3000XLNAFTA
Description
UPS TRUEONLINE 3.0KVA 2400W 9OUT
Manufacturer
Tripp Lite
Series
Smart Online™r
Type
UPSr
Datasheet

Specifications of SU3000XLNAFTA

Power - Rated
3kVA / 2400W
Ac Outlets
9 (UPS)
Features
DB9 and USB Communications, Rack Mount
Backup Time - Max Load
6 minutes
Media Lines Protected
1 - RJ45 Line
Voltage - Output Per Connector
120V (4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R)
Voltage - Input
208V / 30A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA L5-30P
Connector - Ac Output
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R
Size
20.50" L x 9.00" W x 10.25" H (520.7mm x 228.6mm x 260.4mm)
Weight
69 lbs (31.3kg)
Ac Output Connector
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Model #: SU3000XLNAFTA
SmartOnline Expandable Tower UPS System - NAFTA assembled version of SU3000XL
Description
3000VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Upright tower form factor.
Expandable battery runtime with optional BP72V28-3UNAFTA external battery packs. Full-time sine wave 110 or 120V +/-2% output. Online,
double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely
regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V. NEMA L5-30P
input plug; NEMA 5-15R, NEMA 5-15/20R and NEMA L5-30R output receptacles. Network-grade AC surge and noise suppression. Zero transfer
time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and
SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows
and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network
interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated 2-bank PDU switching
supports load shedding and remote-reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. Dataline
surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant
auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. 2-year warranty
and $250,000
Package Includes
Features
SU3000XLNAFTA UPS System
PowerAlert Software and Cabling
Instruction manual with warranty information
SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications
True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage
conditions
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other
UPS types
connected equipment
insurance; extended warranty and service contracts available
Highlights
3000VA / 3KVA on-line, double-conversion, extended-run tower UPS
Maintains sine-wave 110/120V +/-2% output during overvoltages to 138 and
brownouts as low as 65V (50/60Hz auto-sensing)
Simultaneous use communications via HID compliant USB port, serial port,
SNMP/Web card slot and EPO interface
Fault tolerant auto-bypass mode, current monitoring and switched PDU control
via 2 switchable output load banks
Input: NEMA L5-30P (120V) / Output: 4 NEMA5-15R, 4 NEMA5-15/20R & 1
NEMA L5-30R
2 year product warranty / $250,000
Canada only)
Ultimate Lifetime Insurance
E-mail:
Telephone: +(773) 869 1234
Chicago, IL 60609 USA
saleshelp@tripplite.com
1111 West 35th Street
(USA &
Tripp Lite

Related parts for SU3000XLNAFTA

SU3000XLNAFTA Summary of contents

Page 1

... Package Includes SU3000XLNAFTA UPS System PowerAlert Software and Cabling Instruction manual with warranty information Features SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications ...

Page 2

Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 110/120V (+/-2%) values Standard internal battery set offers 14 minutes runtime at half load (1200W) and 5 minutes at full load (2400W) Optional BP72V28-3UNAFTA ...

Page 3

Output circuit breaker 15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered Basic PDU options PDU2430 ( 5-15R outlets) Metered PDU options PDUMV30 ( 5-15/20R outlets) Switched PDU options PDUMH30NET External PDU ...

Page 4

Overvoltage correction 2% output voltage regulation during overvoltages to 138 Undervoltage correction 2% output voltage regulation during undervoltages to 80 Severe undervoltage 2% output voltage regulation during undervoltages to 65 (under 70% load only) correction LEDS ALARMS & SWITCHES LED ...

Page 5

ENVIRONMENTAL Operating Temperature +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Range Storage Temperature +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Range Relative Humidity 0 to 95%, non-condensing AC mode BTU / hr. ...

Page 6

... More information, including related products, owner's manuals, and additional technical specifications, can be found online at www.tripplite.com/en/products/model.cfm?txtModelID=3548. Copyright © 2011 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products. ...

Related keywords