Specifications of SU3000XLNAFTA

Power - Rated
3kVA / 2400W
Ac Outlets
9 (UPS)
Features
DB9 and USB Communications, Rack Mount
Backup Time - Max Load
6 minutes
Media Lines Protected
1 - RJ45 Line
Voltage - Output Per Connector
120V (4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R)
Voltage - Input
208V / 30A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA L5-30P
Connector - Ac Output
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R
Size
20.50" L x 9.00" W x 10.25" H (520.7mm x 228.6mm x 260.4mm)
Weight
69 lbs (31.3kg)
Ac Output Connector
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Overvoltage correction
Undervoltage correction
Severe undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
UPS AC suppression
response time
UPS Dataline
suppression
EMI / RFI AC noise
suppression
PHYSICAL
Installation form
factors supported with
included accessories
Primary form factor
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / inches)
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / cm)
UPS / Power Module
weight (lbs)
UPS / Power Module
weight (kg)
UPS Shipping
dimensions (height x
width x depth / inches)
UPS Shipping
dimensions (height x
width x depth / cm)
Shipping weight (lbs)
Shipping weight (kg)
UPS housing material
Cooling method
2% output voltage regulation during overvoltages to 138
2% output voltage regulation during undervoltages to 80
2% output voltage regulation during undervoltages to 65 (under 70% load only)
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace
battery and fault status information; 4-LED meter displays load and battery charge levels
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown
conditions
Power-fail alarm can be silenced using alarm-cancel switch
2 Switches control off/on power status and alarm-cancel/self-test operation
480
Instantaneous
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
Yes
Tower
Tower
10.2 x 9 x 20.5
26 x 22.9 x 52.1
69.3
31.5
15.2 x 13 x 24
38.7 x 33 x 61
75.2
34.1
Steel
Fan