SC001A2B91-SRZ Lineage Power, SC001A2B91-SRZ Datasheet - Page 6

CONVERTER DC/DC 12.0V 1.2A OUT

SC001A2B91-SRZ

Manufacturer Part Number
SC001A2B91-SRZ
Description
CONVERTER DC/DC 12.0V 1.2A OUT
Manufacturer
Lineage Power
Series
SC001r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of SC001A2B91-SRZ

Output
12V
Number Of Outputs
1
Power (watts)
14W
Mounting Type
Surface Mount
Voltage - Input
24V
Package / Case
6-DIP SMD Module
1st Output
12 VDC @ 1.2A
Size / Dimension
1.10" L x 0.96" W x 0.34" H (27.9mm x 24.4mm x 8.5mm)
Power (watts) - Rated
14.4W
Operating Temperature
-40°C ~ 85°C
Efficiency
85%
Approvals
CE, CSA, IEC, UL, VDE
Output Power
14 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Output Voltage (channel 1)
12 V
Output Current (channel 1)
1.2 A
Isolation Voltage
2.25 KV
Package / Case Size
SMD
Output Type
Isolated
Output Voltage
12 V
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1188-2
CC109121976

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC001A2B91-SRZ
Manufacturer:
SAMTEC INC
Quantity:
3
Data Sheet
October 5, 2009
Characteristic Curves
The following figures provide typical characteristics for the SW001A0C91 (15.0V, 1A) at 25ºC. The figures are
identical for either positive or negative Remote On/Off logic.
Figure 1. Converter Efficiency versus Output
Current.
Figure 2. Derating Output Current versus Local
Ambient Temperature and Airflow.
Figure 3. Typical Output Ripple and Noise, V
nom
LINEAGE
I
O
90
88
86
84
82
80
=80% of I
78
76
74
72
70
0.8
0.6
0.4
0.2
0.0
1.2
1.0
0
0
POWER
10
AMBIENT TEMPERATURE, T
O, max.
3.0 m/ s (600 f t ./ min.)
2.0 m/ s (400 f t ./ min.)
0.2
1.0 m/ s (200 f t ./ min.)
20
Nat ural Convect ion
OUTPUT CURRENT, I
30
TIME, t (1μs/div)
40
0.4
18-36Vdc & 36-75Vdc Input; 3.3-15Vdc Output; 1-3.5A Output Current
50
60
0.6
70
o
(A)
80
A
V
V
V
0.8
I
I
I
O
= 36V
= 75V
= 54V
90
C
IN
100
=V
IN,
110
1
Figure 4. Typical Start-Up Using Remote On/Off,
negative logic version shown.
Figure 5. Transient Response to Dynamic Load Change
from 50% to 75% to 50% of full load.
Figure 6. Typical Start-Up Output Voltage Rise
Characteristic.
SW/SC001/003 Series DC-DC Power Module:
TIME, t (500μs/div)
TIME, t (5ms/div)
TIME, t (1ms/div)
6

Related parts for SC001A2B91-SRZ