HW006A0Y1-S Lineage Power, HW006A0Y1-S Datasheet - Page 17

no-image

HW006A0Y1-S

Manufacturer Part Number
HW006A0Y1-S
Description
CONVERTER DC/DC 1.8V 11W OUT SMD
Manufacturer
Lineage Power
Series
HWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of HW006A0Y1-S

Output
1.8V
Number Of Outputs
1
Power (watts)
11W
Mounting Type
Surface Mount
Voltage - Input
36 ~ 75V
Package / Case
18-DIP SMD Module (6 Leads)
1st Output
1.8 VDC @ 6A
Size / Dimension
1.86" L x 1.16" W x 0.34" H (47.2mm x 29.5mm x 8.6mm)
Power (watts) - Rated
11W
Operating Temperature
-40°C ~ 85°C
Efficiency
82%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HW006A0Y1-S
Manufacturer:
EUPEC/Infineon
Quantity:
1 000
Part Number:
HW006A0Y1-S
Manufacturer:
TYCO
Quantity:
8 000
Data Sheet
October 5, 2009
Feature Description
Remote On/Off
Two remote on/off options are available. Positive logic
turns the module on during a logic high voltage on the
ON/OFF pin, and off during a logic low. Negative logic
remote On/Off, device code suffix “1”, turns the module
off during a logic high and on during a logic low.
To maintain compatibility with LW series power modules
the Remote On/Off pin is optional for the TH (through
hole) version. Standard TH modules have no On/Off pin
fitted. TH modules ordered with device code suffix “1”
are negative logic with the On/Off pin fitted.
Figure 64. Remote On/Off Implementation.
To turn the power module on and off, the user must
supply a switch (open collector or equivalent) to control
the voltage (V
the V
maximum I
should be maintain a logic low level whilst sinking this
current.
During a logic high, the typical V
module is 5.8V, and the maximum allowable leakage
current at V
If not using the remote on/off feature:
For positive logic, leave the ON/OFF pin open.
For negative logic, short the ON/OFF pin to V
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current limiting
continuously. At the point of current-limit inception, the
unit enters hiccup mode. The unit operates normally
once the output current is brought back into its specified
range. The average output current during hiccup is 10%
I
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout
limit, the module operation is disabled. The module will
LINEAGE
O, max
IN
.
(-) terminal. Logic low is 0V ≤ V
POWER
on/off
on/off
I
V
on/off
on/off
on/off
during a logic low is 1mA, the switch
= 5.8V is 10μA.
) between the ON/OFF terminal and
V
ON/OFF
V
IN
IN
(+)
(-)
18-36Vdc & 36-75Vdc Input; 1.0V-5Vdc Output; 4A - 6A Output Current
on/off
generated by the
COM
on/off
V
O
≤ 1.2V. The
IN
(-).
HW/HC004/005/006 Series DC-DC Power Module:
only begin to operate once the input voltage is raised
above the undervoltage lockout turn-on threshold,
V
Once operating, the module will continue to operate until
the input voltage is taken below the undervoltage turn-off
threshold, V
Over Voltage Protection
The output overvoltage protection consists of circuitry
that internally clamps the output voltage. If a more
accurate output overvoltage protection scheme is
required then this should be implemented externally via
use of the remote on/off pin.
Over Temperature Protection
To provide protection in a fault condition, the unit is
equipped with a thermal shutdown circuit. The unit will
shutdown if the overtemperature threshold of 125
exceeded at the thermal reference point T
unit goes into thermal shutdown it will then wait to cool
before attempting to restart.
Output Voltage Programming
Trimming allows the output voltage set point to be
increased or decreased, this is accomplished by
connecting an external resistor between the TRIM pin
and either the V
Figure 65. Circuit Configuration to Trim Output
Voltage.
Connecting an external resistor (R
TRIM pin and the COM pin decreases the output voltage
set point. To maintain set point accuracy, the trim
resistor tolerance should be ±0.1%.
UV/ON
.
V
ON/OFF
V
IN
IN
(+)
(-)
UV/OFF
O
V
(+) pin or the V
.
O
V
TRIM
COM
O
(+)
O
(-) pin (COM pin) .
trim-down
R
R
trim-up
trim-down
) between the
ref
. Once the
o
LOAD
C is
17