DW025AB-M Lineage Power, DW025AB-M Datasheet - Page 2

no-image

DW025AB-M

Manufacturer Part Number
DW025AB-M
Description
CONVERTR DC/DC 5/12V 25W OUT
Manufacturer
Lineage Power
Series
DW025r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of DW025AB-M

Output
5V, 12V
Number Of Outputs
2
Power (watts)
25W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 2.5A
2nd Output
12 VDC @ 1.04A
Size / Dimension
2.80" L x 2.40" W x 0.50" H (71.1mm x 61mm x 12.7mm)
Power (watts) - Rated
25W
Operating Temperature
-40°C ~ 100°C
Efficiency
79%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
13 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
2.5 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1.04 A
Isolation Voltage
500 V
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DW025AB-M
Manufacturer:
LUCENT
Quantity:
26
Part Number:
DW025AB-M
Manufacturer:
VECTRON
Quantity:
157
36 Vdc to 75 Vdc Input; Dual Outputs; 25 W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Note: Two pinouts are available for the DW025-Series Power Modules. The DW025AJ-M, AB-M, BK-M, and
Unless otherwise indicated, specifications apply to all modules over all operating input voltage, resistive load, and
temperature conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2
Input Voltage
I/O Isolation Voltage
Operating Case Temperature
Storage Temperature
Operating Input Voltage
Maximum Input Current
Inrush Transient
Input Reflected-ripple Current, Peak-to-Peak
Input Ripple Rejection (120 Hz)
(V
(5 Hz to 20 MHz, 12 µH source impedance;
T
Considerations section.)
Continuous
Transient (<10 ms)
dc
Transient (1 minute)
C
I
= 0 V to 75 V; I
= 25 °C) (See Figure 11 and Design
CL-M Power Modules, which have both positive and negative outputs, have a common output ground pin
(pinout A). The DW025AA-M, AB-M, AF-M, BB-M, and CC-M Power Modules, which have dual positive out-
puts, have separate output ground pins (pinout B). See Outline Diagrams section.
Parameter
O
Parameter
= I
O
,
max
; see Figure 1.)
Symbol
I
I, max
V
i
2
Symbol
t
I
V
I, trans
T
T
V
stg
C
I
Min
36
Min
–40
–55
Typ
48
25
60
Max
100
500
850
100
125
80
Max
2.0
0.8
75
Lineage Power
April 2008
Unit
mAp-p
°C
°C
V
V
V
V
Unit
Vdc
A
dB
A
2
s

Related parts for DW025AB-M