QW030CL1 Lineage Power, QW030CL1 Datasheet - Page 10

no-image

QW030CL1

Manufacturer Part Number
QW030CL1
Description
CONVERT DC/DC +-15V 30W OUT
Manufacturer
Lineage Power
Series
QWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of QW030CL1

Output
±15V
Number Of Outputs
2
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
8-DIP Module
1st Output
15 VDC @ 1.75A
2nd Output
-15 VDC @ 1.75A
Size / Dimension
2.28" L x 1.45" W x 0.50" H (57.9mm x 36.8mm x 12.7mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 105°C
Efficiency
88%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
QW030CL1
Manufacturer:
amp
Quantity:
239
QW030xx DUAL Series Power Modules: dc-dc Converters;
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs
.
Output Voltage Set-Point Adjustment
(Trim)
Figure 6. QW030-Series Circuit Configuration to
Output Overvoltage Protection
The output overvoltage clamp consists of control
circuitry, independent of the primary regulation loop,
that monitors the voltage on the output terminals. This
control loop has a higher voltage set point than the
primary loop (see the Feature Specifications table). In
a fault condition, the overvoltage clamp ensures that
the output voltage does not exceed V
provides a redundant voltage-control that reduces the
risk of output overvoltage.
Overtemperature Protection
These modules feature overtemperature protection to
safeguard the modules against thermal damage.
When the temperature exceeds the overtemperature
threshold given in the feature specifications table, the
module will limit the available output current in order to
help protect against thermal damage. The overcurrent
inception point will gradually move back to its original
level as the module is cooled below the overtempera-
ture threshold.
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout
limit, the module operation is disabled. The module will
begin to operate at an input voltage between the under-
voltage lockout limit and the minimum operating input
voltage.
10
Feature Descriptions
V
ON/OFF
V
I
I
(+)
(-)
(continued)
Decrease Output Voltage
V
V
TRIM
01
O
COM
2(-)
(+)
R
adj-down
(continued)
O
,
clamp
R
LOAD1
R
LOAD2
,
max
. This
8-715.vf
Thermal Considerations
Introduction
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation of the unit.
Heat-dissipating components inside the unit are ther-
mally coupled to the case. Heat is removed by conduc-
tion, convection, and radiation to the surrounding
environment. Proper cooling can be verified by mea-
suring the case temperature. The case temperature
should be measured at the position indicated in
Figure 7.
Note: Top view, pin locations are for reference only.
Figure 7. QW030-Series Case Temperature
The temperature at this location should not exceed
105 °C. The output power of the module should not
exceed the rated power for the module as listed in the
Ordering Information table.
Although the maximum case temperature of the power
modules is 105 °C, you can limit this temperature to a
lower value for extremely high reliability.
Measurements shown in millimeters and (inches).
(0.55)
14
Measurement Location
V
ON/OFF
V
I
I
(-)
(+)
33 (1.30)
October 2008
V
Data Sheet
V
TRIM
01
COM
02
NC
(+)
(-)
8-2104.a
Lineage Power

Related parts for QW030CL1