JW150G1 Lineage Power, JW150G1 Datasheet - Page 14

no-image

JW150G1

Manufacturer Part Number
JW150G1
Description
CONVERTER DC/DC 2.5V 75W OUT
Manufacturer
Lineage Power
Series
JW150r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JW150G1

Output
2.5V
Number Of Outputs
1
Power (watts)
75W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
2.5 VDC @ 30A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
75W
Operating Temperature
-40°C ~ 100°C
Efficiency
76%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JW150G1-25T
Manufacturer:
LUCENT
Quantity:
27
JW100G and JW150G Power Modules; dc-dc Converters:
36 Vdc to 75 Vdc Input, 2.5 Vdc Output; 50 W to 75 W
Thermal Considerations
Custom Heat Sinks
A more detailed model can be used to determine the
required thermal resistance of a heat sink to provide
necessary cooling. The total module resistance can be
separated into a resistance from case-to-sink (θcs) and
sink-to-ambient (θsa) shown below (Figure 27).
Figure 27. Resistance from Case-to-Sink and
For a managed interface using thermal grease or foils,
a value of θcs = 0.1 °C/W to 0.3 °C/W is typical. The
solution for heat sink resistance is:
14
14
θ
sa
=
P
D
Sink-to-Ambient
(
------------------------ -
T
C
P
T
C
D
T
A
)
θ
θ
cs
cs
T
S
(continued)
θ
sa
T
A
8-1304 (F).e
This equation assumes that all dissipated power must
be shed by the heat sink. Depending on the user-
defined application environment, a more accurate
model, including heat transfer from the sides and bot-
tom of the module, can be used. This equation pro-
vides a conservative estimate for such instances.
EMC Considerations
For assistance with designing for EMC compliance,
please refer to the FLTR100V10 Filter Module Data
Sheet (DS99-294EPS).
Layout Considerations
Copper paths must not be routed beneath the power
module mounting inserts. For additional layout guide-
lines, refer to the FLTR100V10 Filter Module Data
Sheet (DS99-294EPS).
Lineage Power
March 2008
Data Sheet