JAHW075Y1 Lineage Power, JAHW075Y1 Datasheet - Page 12

no-image

JAHW075Y1

Manufacturer Part Number
JAHW075Y1
Description
CONVERTER DC/DC 1.8V 27W OUT
Manufacturer
Lineage Power
Series
JAHWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JAHW075Y1

Output
1.8V
Number Of Outputs
1
Power (watts)
27W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
1.8 VDC @ 15A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
27W
Operating Temperature
-40°C ~ 100°C
Efficiency
88%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
dc-dc Converters; 36 to 75 Vdc Input, 1.8 Vdc Output; 18 W to 36 W
Feature Descriptions
Output Voltage Set-Point Adjustment
(Trim)
Figure 23. Resistor Selection for Decreased
Figure 24. Circuit Configuration to Increase
12
12
100k
10k
1M
V
ON/OFF
CASE
V
I
I
(+)
(–)
(continued)
0
Output Voltage
Output Voltage
% CHANGE IN OUTPUT VOLTAGE (Δ%)
SENSE(+)
SENSE(–)
10
V
TRIM
V
O
O
(+)
(–)
(continued)
20
R
adj-up
30
R
LOAD
8-715 (F).b
8-2470 (F)
40
Output Overvoltage Protection
The output overvoltage protection consists of circuitry
that monitors the voltage on the output terminals. If the
voltage on the output terminals exceeds the overvolt-
age protection threshold, the module will shut down
and restart automatically.
Overtemperature Protection
To provide protection in a fault condition, the unit is
equipped with an overtemperature circuit. In the event
of such a fault, the module enters into an auto-restart
“hiccup” mode with low output voltage until the fault is
removed. Recovery from the overtemperature protec-
tion is automatic after the unit cools below the overtem-
perature protection threshold.
Thermal Considerations
Introduction
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation of the unit.
Heat-dissipating components inside the unit are ther-
mally coupled to the case. Heat is removed by conduc-
tion, convection, and radiation to the surrounding
environment. Proper cooling can be verified by mea-
suring the case temperature. Peak temperature (T
occurs at the position indicated in Figure 25.
Note: Top view, pin locations are for reference only. Measurements
Figure 25. Case Temperature Measurement
(1.20)
shown in millimeters and (inches).
30.5
Location
V
ON/OFF
CASE
V
(1.14)
I
I
(+)
(–)
29.0
+SEN
–SEN
V
TRIM
V
O
O
(+)
(–)
MEASURE CASE
TEMPERATURE HERE
Lineage Power
April 2008
8-716 (F).h
C
)