JC030B-M Lineage Power, JC030B-M Datasheet

no-image

JC030B-M

Manufacturer Part Number
JC030B-M
Description
CONVERTER DC/DC 12V 30W OUT
Manufacturer
Lineage Power
Series
JC030r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JC030B-M

Output
12V
Number Of Outputs
1
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
9-DIP Module
1st Output
12 VDC @ 2.5A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 100°C
Efficiency
83%
Approvals
CSA, UL, VDE
Product
Isolated
Output Power
30 W
Input Voltage Range
18 V to 36 V
Input Voltage (nominal)
24 V
Output Voltage (channel 1)
12 V
Output Current (channel 1)
2.5 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
12 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No
Data Sheet
March 26, 2008
Description
The JC030-Series Power Modules are dc-dc converters that operate over an input voltage range of 18 Vdc to
36 Vdc and provide precisely regulated 2 V, 5 V, 12 V, and 15 V outputs. The outputs are isolated from the
inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum
power ratings of 30 W at a typical full-load efficiency of 81%.
The power modules feature remote on/off, output sense (both negative and positive leads), and output voltage
adjustment, which allows output voltage adjustment from 60% to 110% (80% to 110% for the JC030A-M and
JC030D-M) of the nominal output voltage. For disk-drive applications, the JC030B-M Power Module provides a
motor-start surge current of 3 A.
The modules are PC-board mountable and encapsulated in metal cases. The modules are rated to full load at
100 °C case temperature with no external filtering.
The JC030-Series Power Modules use advanced, surface-
mount technology and deliver high-quality, compact, dc-dc
conversion at an economical price.
Applications
n
n
Options
n
n
n
18 Vdc to 36 Vdc Inputs; 2 Vdc to 15 Vdc Outputs;13 W to 30 W
Distributed power architectures
Telecommunication equipment
Choice of remote on/off configurations
Short pins: 2.79 mm ± 0.25 mm
Heat sinks available for extended operation
(0.110 in. ± 0.010 in.)
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Associa-
‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
JC030-Series Power Modules:
tion.
Small size: 61.0 mm x 57.9 mm x 12.7 mm
Low output noise
Constant frequency
Industry-standard pinout
Metal case
2:1 input voltage range
High efficiency: 81% typical
Overcurrent protection
Remote on/off
Remote sense
Adjustable output voltage
Output overvoltage protection
Case ground pin
UL* 1950 Recognized, CSA
Certified, VDE
Within FCC Class A radiated limits
(2.40 in. x 2.28 in. x 0.50 in.)
0805 (EN60950, IEC950) Licensed
C22.2 No. 950-95

Related parts for JC030B-M

JC030B-M Summary of contents

Page 1

... The power modules feature remote on/off, output sense (both negative and positive leads), and output voltage adjustment, which allows output voltage adjustment from 60% to 110% (80% to 110% for the JC030A-M and JC030D-M) of the nominal output voltage. For disk-drive applications, the JC030B-M Power Module provides a motor-start surge current ...

Page 2

... I T – –40 stg — — — — Symbol Min Typ — — I, max — — I — — — 60 March 26, 2008 Max Unit 50 Vdc 100 °C 110 °C 500 Vdc 850 Vdc Max Unit 36 Vdc 3 0 — mAp-p — dB Lineage Power ...

Page 3

... V O, set JC030C set JC030D-M V JC030A-M V JC030B-M V JC030C-M V All All JC030D-M A-M, B-M, C-M JC030A-M, D-M JC030B-M, C-M JC030A-M, D-M JC030B-M, C-M JC030D-M JC030A-M JC030B-M JC030B trans JC030C-M JC030D-M JC030A-M JC030B-M JC030C-M JC030D-M JC030A-M JC030B-M JC030C-M JC030D-M JC030A-M JC030B-M,C-M All Min ...

Page 4

... Typ Max 0.02 — — — Typ Max 3,900,000 — 100 (3.5) Lineage Power Unit %V O, set %V O, set set %V O, set ms Unit µF M¾ Unit hours g (oz.) ...

Page 5

... Output Voltage Remote Sense Range Output Overvoltage Protection (clamp) Lineage Power Device Symbol All I All V All V All I All V All within O All JC030A-M, D-M JC030B-M, C-M All JC030D clamp JC030A clamp JC030B clamp JC030C clamp Min Typ Max — — 1.0 on/off – ...

Page 6

... Figure 3. JC030A-M Typical Output Voltage (V) I 8-724( 100 (˚C) Figure 4. JC030B-M Typical Output Voltage 8-852(C).b March 26, 2008 -40 - (˚C) CASE TEMPERATURE Variation Over Ambient Temperature Range 12.02 12.00 11.98 11.96 11.94 11.92 11.90 ...

Page 7

... 1 0.8 0.6 0.4 0.2 0 OUTPUT CURRENT, I Figure 6. JC030D-M Typical Output Characteristics Lineage Power 100 (˚C) C Figure 7. JC030A-M Typical Output Characteristics 8-854( Figure 8. JC030B-M Typical Output Characteristics (A) O 8-2692(C) 18 Vdc to 36 Vdc Inputs OUTPUT CURRENT OUTPUT CURRENT 8-721( 8-722(C) 7 ...

Page 8

... Figure 10. JC030D-M Typical Converter Efficiency vs. Output Current 3.0 3.5 4.0 4.5 5.0 Figure 11. JC030A-M Typical Converter Efficiency (A) O 8-723( 36V 4.6 5.6 Figure 12. JC030B-M Typical Converter Efficiency (A) O 8-2691(C) March 26, 2008 OUTPUT CURRENT, I (A) O vs. Output Current 0.5 1.0 1.5 2.0 0 OUTPUT CURRENT ...

Page 9

... Output Current 102 100 98 75 Δ A/10 µs Δ TIME, t (500 µs/div) Figure 14. JC030A, B, C-M Typical Output Voltage for a Step Load Change from 50% to 75% Lineage Power 110 100 1.2 1.4 1.6 1.8 2.0 (A) O Figure 15. JC030D-M Typical Output Voltage for a 8-725(C) ...

Page 10

... S 33 µF IMPEDANCE < 0.1 Ω ˚C, 100 kHz V (-) I 8-203(C) offsets possible S RESISTIVE 0.47 µF SCOPE LOAD 8-513(C).g SENSE(+) CONTACT AND DISTRIBUTION LOSSES V (+)/CASE V (+) LOAD V (–) V (– SENSE(–) 8-749(C). – – ⎞ × 100 % ⎠ – – Lineage Power ...

Page 11

... The unit operates normally once the output current is brought back into its specified range. Lineage Power Remote On/Off Two remote on/off options are available. Positive logic remote on/off turns the module on during a logic-high voltage on the remote ON/OFF pin, and off during a logic low ...

Page 12

... O R adj-up For example, to increase the output voltage of the JC030B by 5%, the external resistor value must be: R adj-up The combination of the output voltage adjustment and sense range and the output voltage given in the Fea- ture Specifications table cannot exceed 110% of the nominal output voltage between the V terminals ...

Page 13

... LOADS, POWER SUPPLIES, AND DATALOGGER, 6.35 (0.25) TALL Note: Dimensions are in millimeters and (inches). Lineage Power Output Overvoltage Protection The output overvoltage clamp consists of control cir- (continued) cuitry, independent of the primary regulation loop, that monitors the voltage on the output terminals. The con- ...

Page 14

... W, the minimum air- flow °C environment is 1.02 ms (200 ft./min.). 14 14 (continued 0.6 Figure 27. JC030D-M Power Dissipation vs. Output Figure 28. JC030A-M Power Dissipation vs. Output –1 March 26, 2008 1.6 2.6 3.8 4.6 OUTPUT CURRENT, I (A) O Current OUTPUT CURRENT, I (A) O Current Lineage Power 6.6 5.6 8-2690(C) 6 8-1154(C) ...

Page 15

... March 26, 2008 18 Vdc to 36 Vdc Inputs; 2 Vdc to 15 Vdc Outputs; Thermal Considerations Forced Convection Cooling 0.0 0.5 1.0 OUTPUT CURRENT, I Figure 29. JC030B-M Power Dissipation vs. Output Current 0.0 0.2 0.4 0.6 0.8 1.0 OUTPUT CURRENT, I Figure 30. JC030C-M Power Dissipation vs. Output Current Lineage Power ...

Page 16

... Thermal Management JC- 1.27 1.52 1.78 2.03 (250) (300) (350) (400) and JW-Series 30 W Board-Mounted Power Modules (TN97-016EPS). -1 (ft./min.) 8-1052(C).a Layout Considerations Copper paths must not be routed beneath the power module standoffs. March 26, 2008 Lineage Power ...

Page 17

... Side View 12.7 (0.50) MAX 5.8 (0.23) MIN Bottom View 5.1 (0.20) 10.16 (0.400) 25.40 50.8 (2.00) (1.000) 35.56 (1.400) (0.19) Lineage Power 57.9 (2.28) MAX V O(+) V I(+) + SEN ON/ 61.0 JC030A-M OFF TRIM DC-DC Power Module MAX CASE - SEM 18-36V 2. OUT ...

Page 18

... TERMINALS 10.16 10.16 (0.400) (0.400 12.7 (0.50) MOUNTING INSERTS MODULE OUTLINE Output Power Device Code Suffix 8 1 March 26, 2008 35.56 (1.400) 25.40 (1.000) 17.78 (0.700) Device Comcode Code JC030D-M 108272170 JC030A-M 107587719 JC030B-M 107587735 JC030C-M 107587768 Lineage Power 8-716(C).l ...

Page 19

... Note: Dimensions are in millimeters and (inches). 1/4 IN. 1/2 IN. 1 IN. 61 (2.4) 1 1/2 IN. 57.9 (2.28) Figure 33. Longitudinal Heat Sink Lineage Power 61 (2.4) 8-724(C).a Figure 34. Transverse Heat Sink Comcode 407243989 407243997 407244706 407244714 407244722 ...

Page 20

... Lineage Power reserves the right to m ake changes to the produc t(s) or inform ation contained herein without notice. No liability is ass res ult of their use or applic ation. No rights under any patent acc om pany the sale of any oduct information. ...

Related keywords