AXA003A0X4Z Lineage Power, AXA003A0X4Z Datasheet - Page 11

CONVERT DC/DC 0.75 5.5V @ 3A SIP

AXA003A0X4Z

Manufacturer Part Number
AXA003A0X4Z
Description
CONVERT DC/DC 0.75 5.5V @ 3A SIP
Manufacturer
Lineage Power
Series
Austin MiniLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXA003A0X4Z

Output
0.75 ~ 5.5V
Number Of Outputs
1
Power (watts)
16W
Mounting Type
Through Hole
Voltage - Input
8.3 ~ 14V
Package / Case
5-SIP Module
1st Output
0.75 ~ 5.5 VDC @ 3A
Size / Dimension
0.90" L x 0.26" W x 0.40" H (22.9mm x 6.6mm x 10.2mm)
Power (watts) - Rated
16.5W
Operating Temperature
-40°C ~ 85°C
Efficiency
91%
Approvals
CSA, EN, UL, VDE
Output Power
17 W
Input Voltage Range
8.3 V to 14 V
Output Voltage (channel 1)
0.75 V to 5.5 V
Output Current (channel 1)
3 A
Package / Case Size
SIP
Output Type
Non-Isolated
Output Voltage
0.75 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1052
CC109104824
Data Sheet
October 2, 2009
Design Considerations
Output Filtering
The Austin MiniLynx
for low output ripple voltage and will meet the
maximum output ripple specification with 1 µF
ceramic and 10 µF tantalum capacitors at the output
of the module. However, additional output filtering
may be required by the system designer for a number
of reasons. First, there may be a need to further
reduce the output ripple and noise of the module.
Second, the dynamic response characteristics may
need to be customized to a particular load step
change.
To reduce the output ripple and improve the dynamic
response to a step load change, additional
capacitance at the output can be used. Low ESR
polymer and ceramic capacitors are recommended to
improve the dynamic response of the module. For
stable operation of the module, limit the capacitance
to less than the maximum output capacitance as
specified in the electrical specification table.
LINEAGE
POWER
TM
12 V SIP module is designed
(continued)
8.3 – 14Vdc Input; 0.75Vdc to 5.5Vdc Output; 3A output current
Austin MiniLynx
Safety Considerations
For safety agency approval the power module must
be installed in compliance with the spacing and
separation requirements of the end-use safety agency
standards, i.e., UL 60950-1, CSA C22.2 No. 60950-1-
03, and VDE 0850:2001-12 (EN60950-1) Licensed.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power
module has extra-low voltage (ELV) outputs when all
inputs are ELV.
The input to these units is to be provided with a fast-
acting fuse with a maximum rating of 6A in the
positive input lead
TM
12V SIP Non-isolated Power Modules:
.
11