ATA010A0X3Z Lineage Power, ATA010A0X3Z Datasheet - Page 15

CONVER DC/DC 0.75 5.5V @ 10A SIP

ATA010A0X3Z

Manufacturer Part Number
ATA010A0X3Z
Description
CONVER DC/DC 0.75 5.5V @ 10A SIP
Manufacturer
Lineage Power
Series
Austin Lynx™ IIr
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheets

Specifications of ATA010A0X3Z

Output
0.75 ~ 5.5V
Number Of Outputs
1
Power (watts)
55W
Mounting Type
Through Hole
Voltage - Input
8.3 ~ 14V
Package / Case
11-SIP Module
1st Output
0.75 ~ 5.5 VDC @ 10A
Size / Dimension
2.00" L x 0.32" W x 0.50" H (50.8mm x 8.1mm x 12.7mm)
Power (watts) - Rated
55W
Operating Temperature
-40°C ~ 85°C
Efficiency
93%
Approvals
CSA, EN, UL, VDE
Output Power
55 W
Input Voltage Range
8.3 V to 14 V
Output Voltage (channel 1)
0.75 V to 5.5 V
Output Current (channel 1)
10 A
Package / Case Size
SIP
Output Type
Non-Isolated
Output Voltage
0.75 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1079
CC109104667
Data Sheet
October 1, 2009
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 33. Note that the airflow is parallel to
the long axis of the module as shown in figure 32. The
derating data applies to airflow in either direction of the
module’s long axis.
Figure 32. T ref Temperature measurement location.
The thermal reference point, T
specifications is shown in Figure 32. For reliable
operation this temperature should not exceed 115
The output power of the module should not exceed the
rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Bottom View
POWER
Top View
Air Flow
ref
used in the
8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current
T
ref
Austin Lynx
o
C.
Figure 33. Thermal Test Set-up.
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. Thermal derating curves
showing the maximum output current that can be
delivered at different local ambient temperature (T
airflow conditions ranging from natural convection and
up to 2m/s (400 ft./min) are shown in the Characteristics
Curves section.
Wind T unnel
TM
II 12V SIP Non-isolated Power Modules:
PWBs
flow
Air
(0.325)
x
8.3_
(3.0)
76.2_
25.4_
(1.0)
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
A
) for
15