AXB030X43-SRZ Lineage Power, AXB030X43-SRZ Datasheet

CONVERTER DC/DC 3-6V 30W SMD

AXB030X43-SRZ

Manufacturer Part Number
AXB030X43-SRZ
Description
CONVERTER DC/DC 3-6V 30W SMD
Manufacturer
Lineage Power
Series
Austin Lynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheets

Specifications of AXB030X43-SRZ

Output
3 ~ 6V
Number Of Outputs
1
Power (watts)
30W
Mounting Type
Surface Mount
Voltage - Input
18 ~ 30V
Package / Case
6-SMD Module
1st Output
3 ~ 6 VDC @ 10A
Size / Dimension
1.30" L x 0.53" W x 0.33" H (33mm x 13.5mm x 8.3mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 85°C
Efficiency
91%
Approvals
CSA, EN, UL, VDE
Output Power
60 W
Input Voltage Range
18 V to 30 V
Output Voltage (channel 1)
3 V to 6 V
Output Current (channel 1)
10 A
Package / Case Size
SMD
Output Type
Non-Isolated
Output Voltage
3 V to 6 V
Product
Non-Isolated / POL
Output Current
10A
Input Voltage
24V
Screening Level
Industrial
Product Length (mm)
33mm
Product Depth (mm)
13.46mm
Mounting Style
Surface Mount
Pin Count
6
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1106-2
CC109106738
Data Sheet
October 2, 2009
Applications
Description
The Austin Lynx
package that can deliver up to 70W of output power with a full load efficiency of 97% at 12Vdc output voltage (V
24Vdc). The module operates over a wide input voltage range (V
regulated output voltage from 5 to 15Vdc, programmable via an external resistor. Standard features include remote
On/Off, adjustable output voltage, remote sense, over current and over temperature protection.
*
** ISO is a registered trademark of the International Organization of Standards
UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
Distributed power architectures
Intermediate bus voltage applications
Telecommunications equipment
Wireless Base stations
Industrial equipment
LANs/WANs
Enterprise Networks
Latest generation IC’s (DSP, FPGA, ASIC) and
Microprocessor powered applications
RoHS Compliant
TM
24V series SIP power module is a non-isolated DC-DC converter in an industry standard
Austin Lynx
20-30Vdc input; 5.0 to 15.0Vdc Output; 70W
TM
Features
24V:Non-isolated Power Module:
IN
97% at 12Vdc full load
Compliant to RoHS EU Directive 2002/95/EC (-Z
versions)
Compliant to ROHS EU Directive 2002/95/EC with
lead solder exemption (non-Z versions)
Wide input voltage range: 20 to 30Vdc
Output voltage programmable via external
resistor:
5Vdc to 15Vdc
High efficiency modules (V
50.8 mm x 12.7 mm x 8.1 mm
(2.00 in x 0.50 in x 0.32 in)
Low output ripple and noise
Monotonic start-up into pre-bias output
Remote On/Off (Positive logic)
Remote Sense
Small size and low profile:
Constant switching frequency
Wide operating temperature range (-40°C to
85°C)
Over current and Over temperature protection
(non-latching)
UL* 60950-1Recognized, CSA
60950-1-03 Certified, and VDE
(EN60950-1) Licensed
ISO** 9001 and ISO 14001 certified
manufacturing facilities
= 20 – 30Vdc) and provides a precisely
Document No: DS06-002 ver.1.07
PDF name: lynx_24v_sip_ds.pdf
IN
= 24Vdc)
C22.2 No.
0805:2001-12
IN
=

Related parts for AXB030X43-SRZ

AXB030X43-SRZ Summary of contents

Page 1

Data Sheet October 2, 2009 Austin Lynx RoHS Compliant Applications Distributed power architectures Intermediate bus voltage applications Telecommunications equipment Wireless Base stations Industrial equipment LANs/WANs Enterprise Networks Latest generation IC’s (DSP, FPGA, ASIC) and Microprocessor powered applications Description TM The ...

Page 2

Data Sheet October 2, 2009 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or ...

Page 3

Data Sheet October 2, 2009 Electrical Specifications (continued) Parameter Output Voltage Set-point ( =25° min O O, max A Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until ...

Page 4

Data Sheet October 2, 2009 Electrical Specifications (continued) Parameter Dynamic Load Response (dI /dt=5A/μ =25° nom A Load Change from Io= 50% to 100 external output capacitors Peak Deviation (Vo = ...

Page 5

Data Sheet October 2, 2009 Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter On/Off Signal interface (On/Off is open collector/drain logic input; Signal referenced ...

Page 6

Data Sheet October 2, 2009 Characteristic Curves The following figures provide typical characteristics for the AXB070X module at 12V, 6A and 25 100 95 90 Vin=24 Vin= OUTPUT CURRENT, I Figure 1. ...

Page 7

Data Sheet October 2, 2009 Characteristic Curves (continued) The following figures provide typical characteristics for the AXB070X module at 5V, 10A and Vin=24 Vin= OUTPUT CURRENT, I Figure 7. Converter ...

Page 8

Data Sheet October 2, 2009 Test Configurations TO OSCILLOSCOPE L TEST 1μ 220μF S Min E.S.R.<0.1Ω 150μF @ 20°C 100kHz NOTE: Measure input reflected ripple current with a simulated source inductance ( 1μH. Capacitor C ...

Page 9

Data Sheet October 2, 2009 Feature Description Remote On/Off TM The Austin Lynx 24V SMT power modules feature an On/Off pin for remote On/Off operation. Positive Logic On/Off signal, device code suffix “4”, turns the module ON during a logic ...

Page 10

... Design Tools section, also calculates the values of R and R for a specific output margin-up margin-down voltage and % margin. Please consult your local Lineage Power technical representative for additional details. LINEAGE POWER TM Austin Lynx 24V: Non-isolated Power Modules: 20– 30Vdc input; 5.0 – 15.0Vdc Output; 70W ...

Page 11

Data Sheet October 2, 2009 Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should always be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for ...

Page 12

Data Sheet October 2, 2009 Mechanical Outline Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0 x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ± 0. x.xxx in ± 0.010 in.) Back ...

Page 13

Data Sheet October 2, 2009 Recommended Pad Layout Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0 x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ± 0. x.xxx in ± 0.010 in.) ...

Page 14

... Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. ...

Related keywords