AXB070X43Z Lineage Power, AXB070X43Z Datasheet - Page 11

CONVERTER DC/DC 5-15V 70W SIP

AXB070X43Z

Manufacturer Part Number
AXB070X43Z
Description
CONVERTER DC/DC 5-15V 70W SIP
Manufacturer
Lineage Power
Series
Austin Lynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXB070X43Z

Output
5 ~ 15V
Number Of Outputs
1
Power (watts)
70W
Mounting Type
Through Hole
Voltage - Input
20 ~ 30V
Package / Case
10-SIP Module
1st Output
5 ~ 15 VDC @ 4.5A
Size / Dimension
2.00" L x 0.32" W x 0.50" H (50.8mm x 8.1mm x 12.7mm)
Power (watts) - Rated
70W
Operating Temperature
-40°C ~ 85°C
Efficiency
97%
Approvals
CSA, EN, UL, VDE
Product
Non-Isolated / POL
Output Power
70 W
Input Voltage Range
20 V to 30 V
Output Voltage (channel 1)
5 V to 15 V
Package / Case Size
SIP
Output Type
Non-Isolated
Output Voltage
5 V to 15 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1153
CC109121480
Wind Tunnel
Data Sheet
October 2, 2009
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 32. Note that the airflow is parallel to
the long axis of the module as shown in figure 32. The
derating data applies to airflow in either direction of the
module’s long axis.
LINEAGE
PWBs
POWER
Figure 32. Thermal Test Set-up.
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
Austin Lynx
The thermal reference point, T
specifications is shown in Figure 33. For reliable
operation this temperature should not exceed 125
The output power of the module should not exceed the
rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
20– 30Vdc input; 5.0 – 15.0Vdc Output; 70W
Figure 33. T ref Temperature measurement location.
Air Flow
TM
24V: Non-isolated Power Modules:
Top View
ref
used in the
T
ref
o
C.
11