APXH006A0X-SRZ Lineage Power, APXH006A0X-SRZ Datasheet - Page 17

CONVERTER DC-DC 0.6 3.63V @ 6A

APXH006A0X-SRZ

Manufacturer Part Number
APXH006A0X-SRZ
Description
CONVERTER DC-DC 0.6 3.63V @ 6A
Manufacturer
Lineage Power
Series
Pico TLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of APXH006A0X-SRZ

Output
0.6 ~ 3.63V
Number Of Outputs
1
Power (watts)
21W
Mounting Type
Surface Mount
Voltage - Input
2.4 ~ 5.5V
Package / Case
10-SMD Module
1st Output
0.6 ~ 3.63 VDC @ 6A
Size / Dimension
0.48" L x 0.48" W x 0.29" H (12.2mm x 12.2mm x 7.3mm)
Power (watts) - Rated
21W
Operating Temperature
-40°C ~ 85°C
Approvals
CSA, EN, UL, VDE
Product
Non-Isolated / POL
Output Power
22 W
Input Voltage Range
2.4 V to 5.5 V
Output Voltage (channel 1)
0.6 V to 3.63 V
Output Current (channel 1)
6 A
Package / Case Size
12.2 mm x 12.2 mm x 7.25 mm
Output Type
Non-Isolated
Output Voltage
0.6 V to 3.63 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1123-2
Data Sheet
April 7, 2011
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 45. The preferred airflow direction
for the module is in Figure 46.
The thermal reference points, T
specifications are also shown in Figure 43. For reliable
operation the temperatures at these points should not
exceed 125
not exceed the rated power of the module (Vo,set x
Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Wind Tunnel
PWBs
POWER
Figure 45. Thermal Test Setup.
o
C. The output power of the module should
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
2.4 – 5.5Vdc input; 0.6Vdc to 3.63Vdc output; 6A output current
ref
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
used in the
Pico TLynx
Figure 46. Preferred airflow direction and location of
hot-spot of the module (Tref).
TM
6A: Non-isolated DC-DC Power Modules
17