ZUP10-20/U TDK Corporation, ZUP10-20/U Datasheet - Page 32

PWR SUP BENCH PROG 0-10V 200W

ZUP10-20/U

Manufacturer Part Number
ZUP10-20/U
Description
PWR SUP BENCH PROG 0-10V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP10-20/U

Number Of Outputs
1
Efficiency
77%
Voltage - Output
0 ~ 10V
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 10 VDC @ 20A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
20A
Input Voltage
85 to 265V
Output Power (max)
200W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Accuracy
0.02% + 8 mV
Brand/series
ZUP
Current, Output
20 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
10 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1668
Q1074270
ZUP10-20/U
ZUP1020/U
4.3.4 Constant Current check
4.3.5 OVP check
Turn off the power supply. Connect an electronic load with suitable voltage and current rating to the
output terminals, as explained in paragraph 3.7.3. Turn-on the power supply. Vary the load current and
check that the unit regulates the output voltage while the load current is smaller than the power supply
current rating. Further increase the load current and check that the power supply regulates the output
current.
Adjust the output voltage to zero using the front panel knob. Momentarily press OVP/UVP pushbutton
until the OVP LED illuminates and the VOLTS display shows OUP. The AMPS display will show the last
setting of the OVP level. Rotate the Adjust knob to 50% of the supply’s voltage rating. Adjust the output
voltage toward it’s maximum and check that the output voltage cannot be increased more than the OVP
setting.
4.3.6 UVP check
4.3.7 Foldback check
4.3.8 Output On/Off
4.3.9 Address setting
4.3.10 Local/Remote operation
Adjust the output voltage to the rated voltage using the front panel knob. Momentarily press OVP/UVP
pushbutton until the UVP LED illuminates and the VOLTS display shows UUP.. The AMPS display will
show the last setting of the UVP level. Rotate the ADJUST knob to 50% of the supply’s voltage rating.
Adjust the output voltage toward it’s minimum and check that the output voltage cannot be decreased
below the UVP setting.
Set the load current to 50% of the supply rating. Momentarily press FOLD pushbutton and check that
the FOLD LED illuminates. Increase the load current toward the supply current rating. Check that the
output voltage and current fall to zero when the load current reaches the Constant Current setting. The
FOLD LED should flash , the ALM LED illuminates and the output is disabled in this condition.
Reduce the load current setting below the power supply current rating and momentarily press FOLD
pushbutton. Check that the output voltage and current recover and FOLD continuously illuminates.
Momentarily press the FOLD pushbutton and check that FOLD LED turns off.
Repeatedly press OUT pushbutton and check that the power supply output is turned On and Off. While
the output is On, the OUT LED illuminates. While the output is Off, the LED is Off.
Momentarily press ADDR pushbutton so the ADDR LED illuminates and the AMPS display shows Addr.
The VOLTS display shows the last address setting. Rotate the ADJUST knob and check that the
VOLTS display varies between 0 and 31.
Repeatedly press REM pushbutton and check that REM LED turns on and off. While the power supply
is at Remote mode, the LED is on and while at Local mode, the LED is off. While the LED is off, turn off
the power supply, remove the DVM and the load wires.