ZUP10-20/U TDK Corporation, ZUP10-20/U Datasheet - Page 57

PWR SUP BENCH PROG 0-10V 200W

ZUP10-20/U

Manufacturer Part Number
ZUP10-20/U
Description
PWR SUP BENCH PROG 0-10V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP10-20/U

Number Of Outputs
1
Efficiency
77%
Voltage - Output
0 ~ 10V
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 10 VDC @ 20A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
20A
Input Voltage
85 to 265V
Output Power (max)
200W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Accuracy
0.02% + 8 mV
Brand/series
ZUP
Current, Output
20 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
10 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1668
Q1074270
ZUP10-20/U
ZUP1020/U
G
grounding
A
ac cables
ac fail
accessories
address
adjustment
alarm status
amps display
auto-parallel
automatic start
B
C
E
F
H
baud rate
bipolar voltage
buffer overflow
calibration
communication
constant current
constant voltage
cooling
cv indicator
cc indicator
error code
external resistor
external voltage
foldback
fuse
humidity
Hyper Terminal
D
display
ZERO-UP USER’S MANUAL INDEX
2
6
46
6
24,26,38
50
46
23
33
30
38
36
46
50
47
27
27
12
23
23
23
46
31
32
23, 29
2, 50
8
48
I
L
O
P
ID control
initialization
J
jacks (front panel)
last setting memory
linking power supplies
local/remote
local sensing
M
multiple loads
maintenance
operational status
otp
output good
over voltage
parallel operation
parity
R
S
rack mounting
remote sensing
registers structure
RS232
RS485
RXD
RX (RS232)
safe start
safety symbols
series operation
shield
status control
SRQ
15, 16
50
42
42
21
30
40
38, 23
14
45
46
37
28
33
48
12
15
45
38, 39
38, 41
41
39
30
3
35
39, 40, 41
45
49
T
U
V
TXD
TX (RS232)
under voltage
volts display
W
wire size
wrong command
41
39
28
23
13
46

Related parts for ZUP10-20/U