CX2044 Xeltek, CX2044 Datasheet - Page 69

SOCKET ADAPTER 44PLCC SUPERPRO5K

CX2044

Manufacturer Part Number
CX2044
Description
SOCKET ADAPTER 44PLCC SUPERPRO5K
Manufacturer
Xeltek
Datasheet

Specifications of CX2044

Module/board Type
*
Positions/sockets
44
Accessory Type
PLCC44 (28*28 Socket Size) Adapter For SuperPro 5000/5004GP
Rohs Compliant
Yes
For Use With/related Products
SuperPro 5000
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
415-1038

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CX20441-11
Manufacturer:
CONEXANT
Quantity:
1 364
Part Number:
CX20441-11
Manufacturer:
CONEXANT
Quantity:
1 500
Part Number:
CX20442-11
Manufacturer:
CONEXANT
Quantity:
465
Edit Auto
To set the order of the batch processing functions, select Edit Auto from the
Options menu. The system displays the Edit Auto screen. Refer to Edit Auto on
page 45 for detailed information on the Edit Auto screen.
Configure the Device
For devices that include the configuration word, you must set the configuration
word before programming to ensure that the chip can be used on the target
system.
The configuration words for some devices are contained in the data file. Therefore,
the system automatically loads the configuration word into the configuration
word buffer when loading the data file.
On some devices, you must manually make the selection. Select Device
Configuration Word from the Device menu to open the ConfigWord screen. Refer
to Device Configuration Word on page 37 for detailed information about the
ConfigWord screen.
Review the Device Information
Some devices must meet some special requirements for programming a chip,
including special algorithms conventions. Read the device manual or instructions
carefully and adjust the operation steps or buffer data as needed. If an adapter is
required for programming, the system displays information about the adapter in
the device information screen. Refer to Dev. Information on page 35 for detailed
information about the device information display.
Execute Programming
Insert the chip properly into the socket. If the prompt information indicates a need
for an adaptor, you may purchase the adapter.
The operation steps for programming a chip are follows:
Superpro
Program
Blank Check 
Notes:You can skip this step if the chip is brand new. 
®
The Blank Check fails on electrically erasable chips containing some
information. In this case, perform the Erase operation first. You do not
need to erase EPROM chips for which the data can be overwritten.