CDB5463U Cirrus Logic Inc, CDB5463U Datasheet - Page 15

no-image

CDB5463U

Manufacturer Part Number
CDB5463U
Description
BOARD EVAL & SOFTWARE CS5463 ADC
Manufacturer
Cirrus Logic Inc
Type
A/Dr
Datasheets

Specifications of CDB5463U

Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
CS5463
Primary Attributes
1-Phase, Energy-to-Frequency Output
Secondary Attributes
GUI, USB, SPI Interfaces
Product
Data Conversion Development Tools
Maximum Clock Frequency
4 MHz
Interface Type
USB
Supply Voltage (max)
5 V
Supply Voltage (min)
3.3 V
For Use With/related Products
CS5463
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1553
2.5.1
In the Offset & Gain fields, the offset and gain registers for both channels are displayed in hexadecimal
and decimal formats. These registers can be modified directly by typing the desired value in the hexadec-
imal display fields. There are two types of offset registers: DC offset and AC offset. The AC Offset register
only affects the RMS register values. The DC & AC offset registers are two's complement numbers whose
values ranges from -1 to +1. The gain register value ranges from 0 to 4.
2.5.2
Offset and gain calibrations can be performed on both the voltage and current channels of the CS5463.
Because the initial values in the calibration registers will affect the results of the calibrations, it is generally
a good idea to software reset the CS5463 before running calibrations. A software reset will reset these
registers back to the default values of zero offset and unity gain. Offset calibration should be performed
before gain calibration to ensure accurate results.
2.5.2.1
The calibration value(s) will automatically update when the calibration is completed.
2.5.2.2
The calibration value(s) will automatically update when the calibration is completed.
The Calibration Window also contains the Power Offset Register display and adjustment. The user can
read and write the value in the power offset (Poff) register.
DS805DB2
1. Ground the channel(s) you want to calibrate directly at the channel header(s) J17 and J22 for the voltage
2. Press the corresponding AC or DC offset calibrate button (Cal V, Cal I, or Cal Both) beside or below the
1. Attach an DC or AC calibration signal to the screw terminals, and make sure the corresponding channel
2. Press the corresponding AC or DC gain calibrate button (Cal V, Cal I, or Cal Both) beside or below the Gain
channel, and J24 and J26 for the current channel. The channel(s) could also be grounded directly at the
screw terminals.
corresponding offset registers fields.
headers (J17, J22, J24, and J26) are set to the input position.
Registers fields.
Offset / Gain Register
Performing Calibrations
Offset Calibrations
Gain Calibrations