CDB5463U Cirrus Logic Inc, CDB5463U Datasheet - Page 23

no-image

CDB5463U

Manufacturer Part Number
CDB5463U
Description
BOARD EVAL & SOFTWARE CS5463 ADC
Manufacturer
Cirrus Logic Inc
Type
A/Dr
Datasheets

Specifications of CDB5463U

Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
CS5463
Primary Attributes
1-Phase, Energy-to-Frequency Output
Secondary Attributes
GUI, USB, SPI Interfaces
Product
Data Conversion Development Tools
Maximum Clock Frequency
4 MHz
Interface Type
USB
Supply Voltage (max)
5 V
Supply Voltage (min)
3.3 V
For Use With/related Products
CS5463
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1553
5.16 Commands
All commands are 8 bits in length. Any command byte value that is not listed in this section is invalid. Commands
that write to registers must be followed by 3 bytes of data. Commands that read data can be chained with other com-
mands (e.g., while reading data, a new command can be sent which can execute during the original read). All com-
mands except register reads, register writes, and SYNC0 & SYNC1 will abort any currently executing commands.
5.16.1 Start Conversions
5.16.2 SYNC0 and SYNC1
The serial port can be initialized by asserting CS or by sending three or more consecutive SYNC1 commands fol-
lowed by a SYNC0 command. The SYNC0 or SYNC1 can also be sent while sending data out.
5.16.3 Power-up/Halt
If the device is powered-down, Power-Up/Halt will initiate a power on reset. If the part is already powered-on, all
computations will be halted.
5.16.4 Power-down and Software Reset
To conserve power the CS5463 has two power-down states. In stand-by state all circuitry, except the analog/digital
clock generators, is turned off. In the sleep state all circuitry, except the command decoder, is turned off. Bringing
the CS5463 out of sleep state requires more time than out of stand-by state, because of the extra time needed to
re-start and re-stabilize the analog oscillator.
DS678F2
Initiates acquiring measurements and calculating results. The device has two modes of acquisition.
B7
B7
B7
B7
1
1
1
1
SYNC
C3
S[1:0]
B6
B6
B6
B6
1
1
0
0
B5
B5
B5
B5
1
1
1
0
0 = Perform a single computation cycle
1 = Perform continuous computation cycles
0 = Last byte of a serial port re-initialization sequence.
1 = Used during reads and serial port initialization.
00 = Software Reset
01 = Halt and enter stand-by power saving state. This state allows quick power-on
10 = Halt and enter sleep power saving state.
11 = Reserved
Modes of acquisition/measurement
Power-down state
B4
B4
B4
B4
S1
0
1
0
B3
C3
B3
B3
B3
S0
1
0
B2
B2
B2
B2
0
1
0
0
B1
B1
B1
B1
0
1
0
0
SYNC
B0
B0
B0
B0
0
0
0
CS5463
23