MAX11068EVKIT+ Maxim Integrated Products, MAX11068EVKIT+ Datasheet - Page 12

no-image

MAX11068EVKIT+

Manufacturer Part Number
MAX11068EVKIT+
Description
KIT SMART BATT MEASUREMENT 12CH
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX11068EVKIT+

Main Purpose
Power Management, Battery Monitor, Car
Utilized Ic / Part
MAX11068
Primary Attributes
Monitors Current, Voltage, Temperature
Secondary Attributes
1 ~ 12 Cell- Li-Ion, 1 ~ 12 Cell- NiMH
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Embedded
-
MAX11068 Evaluation System
Table_8._Threshold_Registers
*The maximum voltage setting is 5.0000V.
Table_9._AIN1_and_AIN2_Controls
*These bits work in parallel with the ALRMUTEN and ALRMOTEN registers.
For all the threshold registers, the data (D[11:0]) is con-
tained in the upper 12 bits of the 16-bit register. When
entering data into the Under-Temperature_ Threshold_
(AINUT) and Over-Temperature_ Threshold (AINOT)
edit boxes, enter only the hex value of the upper 12 bits.
The lower nibble of all threshold registers are ignored
during a write and are read back as zeros.
The Voltage_Measurements tab (Figure 7) displays the
results for the ADC conversions on cells 1–12, as well
as the results for TOTAL, MAXCELL, and MINCELL. The
register contents are displayed in the grid as voltages.
The checkboxes at the top of the tab and their associ-
ated Configure_ Cells_ (F9) button are used to enable
a cell for measurement. These checkboxes have the
same function as the CELL_EN checkboxes on the
Configuration tab. See the ADC Scan section for details
on setting up and initiating an ADC scan.
12_ _ ______________________________________________________________________________________
Overvoltage Clear (0x18)
Overvoltage Set (0x19)
Undervoltage Set (0x1A)
Undervoltage Clear (0x1B)
Cell Mismatch (0x1C)
Auxiliary Analog Input Overtemperature (0x1E)
Auxiliary Analog Input Undertemperature (0x1F)
Conversion_Value
Under_Temperature_Enable_(COLDEN)
Over_Temperature_Enable_(HOTEN)
Update_Active_Device
Update_All_Devices
THRESHOLD_REGISTER_(ADDRESS)
AIN__GUI_CONTROL
Voltage Measurements Tab
CONTROL_TYPE
Checkbox
Checkbox
Button
Button
Label
GUI_CONTROL
Displays the 12-bit AIN_ conversion value
Configures the COLDEN bit to enable/disable the ALRTTHOT
alarm*
Configures the HOTEN bit to enable/disable the ALRTTCOLD
alarm*
Configures the COLDEN and HOTEN bits of the active device
Configures the COLDEN and HOTEN bits of all devices
The auxiliary analog inputs (AIN1 and AIN2), diagnostic
(DIAG), and failure mode effects analysis (FMEA) reg-
isters are accessed from this tab (Figure 8). The tab is
divided into four group boxes: AIN1,_ AIN2, DIAG,_ and_
Failure_ Mode_ Effects_ Analysis_ (FMEA). The DIAG
group box displays the 12-bit result of the self-diagnostic
measurement and the FMEA group box displays the
FMEA alerts and provides access to their associated
mask bits. The AIN_ group boxes provide the controls
listed in Table 9.
The AIN1, AIN2, and DIAG conversions must first be
enabled before a valid conversion value can be read
from the AIN or DIAG registers. A scan of the AIN_
channel is enabled by selecting the AIN_EN checkbox
located on the Enables tab (Figure 10). A self-diagnos-
tics conversion is enabled by selecting the DIAGEN_
checkbox located on the Enables tab. See the Enables
Tab and ADC Scan sections.
OVTHRCLR
UVTHRCLR
OVTHRSET
UVTHRSET
MSMTCH
AINOT
AINUT
DESCRIPTION
DISPLAY/DATA_INPUT_FORMAT
AIN1/DIAG/FMEA Tab
Voltage*
Voltage*
Voltage*
Voltage*
Voltage*
Hex
Hex

Related parts for MAX11068EVKIT+