MAX11068EVKIT+ Maxim Integrated Products, MAX11068EVKIT+ Datasheet - Page 8

no-image

MAX11068EVKIT+

Manufacturer Part Number
MAX11068EVKIT+
Description
KIT SMART BATT MEASUREMENT 12CH
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX11068EVKIT+

Main Purpose
Power Management, Battery Monitor, Car
Utilized Ic / Part
MAX11068
Primary Attributes
Monitors Current, Voltage, Temperature
Secondary Attributes
1 ~ 12 Cell- Li-Ion, 1 ~ 12 Cell- NiMH
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Embedded
-
MAX11068 Evaluation System
When the SETLASTADDRESS command sequence is
complete, the software updates the grids on the Device_
Addresses_ (0x01) tab and the Thresholds,_ Voltage_
Measurement,_AIN/DIAG/FMEA,_Alert/Status,_Enables,_
Configuration, and Broadcast/Version/Freq tabs.
The Device_ Addresses_ (0x01) tab is initialized after
pressing the Set_Last_Address button. The grid contains
the addresses of all the detected devices. Selecting a
cell that contains a device address updates the Active_
Device drop-down list. For a two-device ladder with a
start address of 0x01, the grid would be displayed as
shown in Figure 1.
Note: A device’s address is contained in the lower byte
of its ADDRESS register (bit[5:1]), specified LSB first. A
device address of 0x01 (A[4:0]) would be stored in the
Table_6._ADDRESS_Register
Figure 1. MAX11068 EV Kit Software (Device Address Grid)
Figure 2. MAX11068 EV Kit Software (Device Rows)
8_ _ _______________________________________________________________________________________
Bit_15
Bit_7
0
1
Bit_14
Bit_6
0
0
Device Addresses Grid
Grid Initialization
Bit_13
Bit_5
A0
0
Bit_12
Bit_4
LA4
A1
device’s ADDRESS register as 0xA0 (A[0:4]). This rela-
tionship is displayed in the Active_ Device drop-down
list.
The Thresholds,_ Voltage_ Measurement,_ AIN/DIAG/
FMEA,_ Alert/Status,_ Enables,_ Configuration, and
Broadcast/Version/Freq tabs all include grids that dis-
play the contents of the selected device registers. These
tabs are all updated to contain n number of rows, where
n equals the total number of detected devices.
For a two-device ladder with a start address of 0x01,
the grids on each tab are configured with two rows, as
shown in Figure 2. The number of columns in each grid is
set by the number of registers associated with that grid.
In addition, each row has an associated device number
button that, when pressed, sets that device as the active
device, updating the Active_Device drop-down list.
Bit_11
Bit_3
LA3
A2
Bit_10
Bit_2
LA2
A3
Bit_9
Bit_1
LA1
A4
Register Grids
Bit_8
Bit_0
LA0
0