BMA150-SHUTL Bosch Sensortec, BMA150-SHUTL Datasheet - Page 13

BMA150 DAUGHTERCARD FOR DEV KIT

BMA150-SHUTL

Manufacturer Part Number
BMA150-SHUTL
Description
BMA150 DAUGHTERCARD FOR DEV KIT
Manufacturer
Bosch Sensortec
Datasheets

Specifications of BMA150-SHUTL

Sensor Type
Accelerometer, 3 Axis
Sensing Range
±2g, 4g, 8g
Interface
I²C, SPI
Sensitivity
64, 128, 256 LSB/g
Voltage - Supply
2.4 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
BMA150
For Use With
DM180021 - KIT STARTER MPLAB FOR PIC18F MCU
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
828-1009
If a not-latched interrupt is generated, the device waits in the normal mode till the interrupt
condition disappears. The minimum duration of interrupt activation is 330µs. If no interrupt is
generated, the sensor IC goes to sleep mode for a defined time (wake_up_pause).
For more details on the wake-up functionality, please refer to chapter 7.3
3.1.5 Wake_up_pause
These bits (address 15h, bit 2 and 1) define the sleep phase duration between each automatic
wake-up.
Table 5: Settings of wake_up_pause
Note: The accuracy of the wake-up timer is about ±30%.
3.1.6 Shadow_dis
BMA150 provides the possibility to block the update of data MSB while LSB are read out. This
avoids a potential mixing of LSB and MSB of successive conversion cycles. When this bit
(address 15h, bit 3) is at 1, the blocking procedure for MSB is not realized and MSB only
reading is possible.
Rev. 1.6
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
wake_up_pause<1:0>
00
01
10
11
Triaxial, digital acceleration sensor
Sleep phase duration
Data sheet
BMA150
Page 13
2560 ms
320 ms
20 ms
80 ms
Bosch Sensortec
30 October 2008