BMA150-SHUTL Bosch Sensortec, BMA150-SHUTL Datasheet - Page 47

BMA150 DAUGHTERCARD FOR DEV KIT

BMA150-SHUTL

Manufacturer Part Number
BMA150-SHUTL
Description
BMA150 DAUGHTERCARD FOR DEV KIT
Manufacturer
Bosch Sensortec
Datasheets

Specifications of BMA150-SHUTL

Sensor Type
Accelerometer, 3 Axis
Sensing Range
±2g, 4g, 8g
Interface
I²C, SPI
Sensitivity
64, 128, 256 LSB/g
Voltage - Supply
2.4 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
BMA150
For Use With
DM180021 - KIT STARTER MPLAB FOR PIC18F MCU
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
828-1009
evaluates the acceleration data with respect to interrupt criteria defined by the user. An interrupt
output can be generated and trigger the system master. The wake-up mode is used for ultra-low
power applications where inertial factors can be an indicator to change the activity mode of the
system.
The following table shows values calculated for the average current consumption during the
wake-up mode of the BMA150. The power consumption in wake-up mode is dependent on the
duration of the interrupt algorithm (number of data acquisitions) and the bandwidth (for more
details on setting of the bandwidth please refer to chapter 3.1.3).
Table 13: Average current consumption in self wake-up mode using high-g or low-g interrupt
Pause [ms]
Durations of the pause values can vary for about ±30% due to the accuracy of the ultra-low-
power oscillator implemented within the sensor.
For estimating the typical current consumption in wake-up mode the following formula can be
applied:
i_self_wake_up = (i_DD · t_active + i_DDsbm · wake-up-pause) / (t_active + wake-up-pause)
With the approximation:
With the following parameters:
Rev. 1.6
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
2,560
360
20
80
t_active = 1ms + 0.333ms · (4
i_DD
i_DDsm
wake_up_pause
n
Bandwidth
(@ 1,500Hz)
16.3
5.1
1.9
1.1
Current consumption during BMA150 wake-up mode [µA]
(depending on bandwidth, calculated using typical values)
Current in normal mode
Current in sleep mode
Setting of wake-up pause
number of data points in any-motion logic
(n=0 for high-g threshold and low-g threshold interrupt,
n=3 for any-motion logic)
Setting of bandwidth (750-25 Hz),
for 1500Hz t_active = 1ms + 0.333ms · (1500/bandwidth) · n
Triaxial, digital acceleration sensor
(@ 750Hz)
21,8
6.6
2.3
1.2
750 / bandwidth) + 0.333ms · (1500 / bandwidth) · n
Data sheet
BMA150
Page 47
(@375Hz)
31.8
9.7
3.0
1.3
(@190Hz)
48.4
15.4
4.4
1.5
(@100Hz)
71.6
25.0
6.9
1.9
(@50Hz)
Bosch Sensortec
102.9
42.3
12.0
2.6
30 October 2008
(@25Hz)
134.7
68.4
21.3
4.1

Related parts for BMA150-SHUTL