M30290T2-CPE User’s Manual
(2) Target Status LEDs
The target status LEDs indicate the target MCU’s power supply and operating status.
Table 1.3 lists the definition of each target status LED.
Table 1.3 Definitions of the target status LEDs
(3) System Reset Switch
By pressing the system reset switch, you can initialize the emulator system.
Table 1.4 shows the functions of the system reset switch depending on the state of the emulator.
Table 1.4 Functions of the system reset switch
(4) Power Connector (J1)
This is a connector for connecting the power supply to this product. For details, refer to “2.4 Connecting the Power Supply for
the Emulator” (page 22).
(5) USB Cable Connector (J2)
This is a USB cable connector for connecting the host machine to this product. For details, “2.5 Connecting the Host Machine”
(page 23).
REJ10J0494-0200 Rev.2.00 July 16, 2005
POWER
CLOCK
RESET
RUN
When the user’s program is halted
When the user’s program is executed
Notes on a System Reset:
Name
State of Emulator
After pressing the system reset switch, restart the emulator debugger. Otherwise the display of emulator
debugger and the actual value (in the emulator) may not match.
When the emulator debugger does not start up normally even after rebooting, turn off the emulator and then turn
on again.
Number
LED3
LED4
LED5
LED6
Orange
Green
Green
Color
Red
Status
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Initializes the emulator and waits for a command from the
emulator debugger
Stops the user’s program, initializes the emulator, and
waits for a command from the emulator debugger.
Power is supplied to the target MCU.
Power is not supplied to the target MCU.
Clock is output from the target MCU.
Clock is not output from the target MCU.
Target MCU is being reset.
Target MCU is not being reset.
User program is being executed.
User program is not being executed.