HS2556EPI61H Renesas Electronics America, HS2556EPI61H Datasheet - Page 103

no-image

HS2556EPI61H

Manufacturer Part Number
HS2556EPI61H
Description
EMULATOR BASE H8SX/2556
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HS2556EPI61H

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Acquires trace information in the specified range.
[Start Address]:
[Stop Address]:
[Cyclic]:
Sets the event points that are required to start or stop trace acquisition when the start or end address is accessed,
respectively.
Point to Point mode is an easy method to set up the event mode. The event to start or sop trace acquisition is an
access to a single address.
Select [Cyclic] to continue acquisition of the trace information only in the specified address range.
Note: This function automatically configures a sequence of event points. Note, however, that an unexpected
Point to Point
result may arise. In such cases, modify the setting of the sequence in the [Event Sequencing] dialog box.
When this box is checked, the event sequencing is configured so that the events reset
themselves which causes tracing to be restarted when the start event occurs after the stop event.
Address where trace acquisition starts
Address where trace acquisition stops
Figure 5.34 Range Trace Setting (Point to Point)
81

Related parts for HS2556EPI61H