SUPERPRO 5000 Xeltek, SUPERPRO 5000 Datasheet - Page 68

PROGRAMMER UNIV STANDALONE W/USB

SUPERPRO 5000

Manufacturer Part Number
SUPERPRO 5000
Description
PROGRAMMER UNIV STANDALONE W/USB
Manufacturer
Xeltek
Series
SuperPro 5000r
Type
Universal, Stand Aloner
Datasheet

Specifications of SUPERPRO 5000

Contents
Programmer, Power Supply Adapter, Software, Cables and Documentation
Ic Product Type
Programmer, Universal
Ic Interface Type
USB
No. Of Devices Supported
41848
Kit Contents
Programmer W/ A DIP48 Adapter, AC Adapter, Software CD, USB2.0 Cable, And User's Manual
Rohs Compliant
Yes
For Use With/related Products
E/EPROM, FLASH, PLD, Micros and more listed on Device Sheet. 44,000+ Devices Supported.
For Use With
415-1037 - SOCKET ADAPTER 32PLCC SUPERPRO5K415-1045 - SOCKET ADAPTER 84PLCC SUPERPRO5K415-1044 - SOCKET ADAPTER 28SOIC SUPERPRO5K415-1043 - SOCKET ADAPTER 28SSOP SUPERPRO5K415-1042 - SOCKET ADAPTER 56TSOP SUPERPRO5K415-1041 - SOCKET ADAPTER 40TSOP SUPERPRO5K415-1040 - SOCKET ADAPTER 16SOP SUPERPRO5K415-1039 - SOCKET ADAPTER 48TSOP SUPERPRO5K415-1038 - SOCKET ADAPTER 44PLCC SUPERPRO5K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
415-1036
Set Options
Select Operation Option from the Option menu to open the Operation Option
screen. Set each of the following options:
Superpro
After confirmation, the system loads data into the buffer.
Make sure the loaded data is correct by viewing on the Buffer Edit
window. Refer to Buffer Menu on page 26 for detailed information.
To read the data from a master chip, complete the following
steps: – Insert the master chip in the socket. 
– Select Read on the Device Operation window of the main screen. The
– Make sure the loaded data is correct by viewing on the Buffer Edit window.
– If desired, you can save the data to a disk for later use. Refer to Save on
Insertion Test option to indicate whether to check the pin contact before
programming 
Device ID Check option to indicate whether to check the ID of the device
before programming 
Beeper option to indicate whether the beeper beeps when the operation
succeeds or fails 
Auto Increment Function option to indicate an automatic increase in the label
number written to each chip 
Address Change option to indicate a different start and end address for the
programming zone of the device 
Verification Mode option to select a specific VCC voltage to ensure that the
chip is programmed correctly 
Note: Some Hex or S record files contain non‐zero file start address. In this
Note: The read function is not available for some devices, including those
system copies the data from the master chip into the memory buffer. 
Refer to Buffer Menu on page 26 for detailed information. 
page 25 for detailed information on saving files. 
®
5000 User’s Guide
case, enter the start address in the File Address box.
that have been encrypted.
68