Y92S-38 Omron, Y92S-38 Datasheet - Page 18

LOCK KEY PEN FOR H3DS RELAYS

Y92S-38

Manufacturer Part Number
Y92S-38
Description
LOCK KEY PEN FOR H3DS RELAYS
Manufacturer
Omron
Series
H3DSr
Datasheets

Specifications of Y92S-38

Accessory Type
Tool - Lock Key Pen
For Use With/related Products
H3DS Series
For Use With
H3DS-SLCAC24-230/DC24 - TIMER CAGE CLAMP 17.5MM 4MODESH3DS-MLCAC24-230/DC24-48 - TIMER CAGE CLAMP 17.5MM 8MODESZ2395 - RELAY TIME DELAY 4MODE DIN MNTZ2394 - RELAY TIME DELAY 1MODE DIN MNTZ2393 - RELAY TIME DELAY 8MODE DIN MNTZ2392 - RELAY TIME DELAY 1MODE DIN MNT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92S38
Z2396
H3DS-F
Specifications
I
Note:
I
Note:
I
Note: DC ripple rate: 20% max.
Item
Operating mode
Output type
External connections
Terminal block
Terminal screw tightening torque
Mounting method
Attachment
Approved standards
Rated supply voltage (See note.)
Operating voltage range
Power reset
Reset voltage
Power consumption
Voltage input
Control output
Ambient temperature
Ambient humidity
Time scale display
0.1s
1 s
0.1 m
1 m
0.1 h
1 h
Time Ranges
General
Ratings
Can be mounted to 35 mm D I N Track with a plate thickness of 1 to 2.5 mm.
When the time setting dial is set to “0” for any time scale, the output will operate instantaneously.
Time range
0.1 to 1.2
1 to 12 s
0.1 to 1.2 min
1 to 12 min
0.1 to 1.2 h
1 to 12 h
H3DS-F
Repeat-cycle with independent ON-time/OFF-time settings
Relay: SPDT
Screw terminal, cage clamp type
Screw terminal type: Clamps two 2.5-mm
Cage clamp type: Clamps two 1.5-mm
0.98 N • m max.
DIN track mounting (see note)
Nameplate label
UL508, CSA C22.2 No.14
Conforms to EN61812-1, IEC60664-1 (VDE0110) 4 kV/2, VDE0106/P 100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15;
250 V 1 A/DC-13; 30 V 0.1 A)
24 to 230 VAC (50/60 Hz)/24 to 48 VDC
85% to 110% of rated supply voltage
Minimum power-off time: 0.1 s
2.4 VAC/DC max.
AC: 33 VA max./2.2 W max. (typical: 31 VA/2.0 W) at 230 VAC;11 VA max./1.9 W max.
(typical: 9.7 VA/1.7 W) at 100 to 120 VAC
DC: 0.7 W max. (typical: 0.6 W) at 24 VDC;1.4 W max. (typical: 1.2 W) at 48 VDC
Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pF
Load connectable in parallel with inputs (terminals B1 and A1).
H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC
L-level: 0 to 2.4 VAC/DC
Contact output: 5 A at 250 VAC with resistive load (cos φ = 1);
5 A at 30 VDC with resistive load (cos φ = 1)
Operating: –10 ° C to 55 ° C (14 ° F to 131 ° F) with no icing
Storage: –25 ° C to 65 ° C (-13 ° F to 145 ° F) with no icing
Operating: 35% to 85%
2
max. bar terminals without sleeves.
2
max. bar terminals without sleeves.
H3DS-F

Related parts for Y92S-38