Y92S-38 Omron, Y92S-38 Datasheet - Page 46

LOCK KEY PEN FOR H3DS RELAYS

Y92S-38

Manufacturer Part Number
Y92S-38
Description
LOCK KEY PEN FOR H3DS RELAYS
Manufacturer
Omron
Series
H3DSr
Datasheets

Specifications of Y92S-38

Accessory Type
Tool - Lock Key Pen
For Use With/related Products
H3DS Series
For Use With
H3DS-SLCAC24-230/DC24 - TIMER CAGE CLAMP 17.5MM 4MODESH3DS-MLCAC24-230/DC24-48 - TIMER CAGE CLAMP 17.5MM 8MODESZ2395 - RELAY TIME DELAY 4MODE DIN MNTZ2394 - RELAY TIME DELAY 1MODE DIN MNTZ2393 - RELAY TIME DELAY 8MODE DIN MNTZ2392 - RELAY TIME DELAY 1MODE DIN MNT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92S38
Z2396
H3DS-X
Precautions
I
Do not change the time scale or operating mode while the Timer is
in operation, or malfunction could result.
I
The H3DS Series has a transformerless power supply system.
Touching the input terminal while power is being supplied can
cause you to get an electrical shock.
Use the bar terminal for wiring the H3DS. Using a stranded-wire
terminal may cause a short-circuit due to a stray wire entering into
the Timer.
Both AC and DC power supplies can be connected to the power
input terminals without regard to polarity.
A DC power supply can be connected if its ripple factor is 20% or
less and the mean voltage is within the rated operating voltage
range of the Timer.
Make sure that the voltage is applied within the specified range, or
the internal elements of the Timer may be damaged.
Connect the power supply voltage through a relay or switch in a
way so that the voltage reaches a fixed value at once. If this is not
done, the Timer may not be reset, or a timer error could result.
I
Several H3DS-XL@ @ @ @ Timers can be mounted together side by side.
Setting Changes
Power Supplies
Installation
!WARNING
!WARNING
!WARNING
!WARNING
H3DS
t
H3DS
t: Mounting clearance (mm)
t
H3DS
DIN track
I
The following conditions must be met so that the built-in timer
in the H3DS conforms to EN61812-1:
The output section of the H3DS is provided with basic isola-
tion only. To ensure reinforced isolation required by the
EN61812-1, provide supplementary basic isolation on the
load side connected to the output.
The H3DS itself is designed according to the following:
• Overvoltage category III
• Pollution degree 2
On the above basis:
Operation parts on the front and bottom: reinforce isolation
• With clearance of 5.5 mm and creepage distance of 5.5 mm
Output: Basic isolation
• With clearance of 3 mm and creepage distance of 3 mm at
I
When using the Timer in an area with excess electrical noise,
separate the Timer, wiring, and the equipment which gener-
ates the input signals as far as possible from the noise
sources. Shield the input signal wiring to prevent electrical
interference.
Organic solvents (such as paint thinner), as well as very
acidic or basic solutions, can damage the outer casing of the
Timer.
Do not use the Timer in places where it is exposed to dust,
corrosive gas, or direct sunlight.
When storing the Timer, make sure that the ambient tempera-
ture and humidity are within the rated values. If the timer has
been stored at an ambient temperature of –10 ° C or below,
leave the Timer at room temperature for at least three hours
before using the Timer.
I
Before carrying out a voltage withstand test between the
electrical circuitry and non-current-carrying metal part of the
Timer, remove the Timer from the control board (if it’s
mounted there) or short-circuit the circuitry of the power
board. This prevents the internal circuitry of the Timer from
damage.
at 230 VAC
230 VAC
Precautions for EN61812-1
Conformance
Environment
Voltage Withstand Test
H3DS-X

Related parts for Y92S-38