P2CF-11-E Omron, P2CF-11-E Datasheet

no-image

P2CF-11-E

Manufacturer Part Number
P2CF-11-E
Description
SOCKET 11-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr
Series
-r
Datasheets

Specifications of P2CF-11-E

Number Of Positions
11
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Features
-
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
11
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
For Use With/related Products
Multiple Series
For Use With
Z2998 - RELAY TIMER DGTL SPDT 100/240VACZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF11E
Upgraded 1/16, 1/8, and 1/4 DIN Controllers, the Best-selling E5@N Series.
Basic Type (Renewal E5@N) and Advanced Type (New E5@N-H).
• Improved indication accuracy and preventive maintenance (Basic Type E5@N).
• New high-performance Controllers (Advanced Type E5@N-H).
• Easy-to-use one-touch operation with PF Key (Only for 1/8 and 1/4 DIN).
• Logic operations.
Digital Temperature Controllers/Digital Controllers
E5@N/E5@N-H
1/16 DIN
E5CN
Basic Type (Renewal E5@N)
1/8 DIN
E5EN
1/4 DIN
E5AN
E5@N Series
1/16 DIN
E5CN-H
Advanced Type (New E5@N-H)
E5EN-H
1/8 DIN
E5AN-H
1/4 DIN
1 1

Related parts for P2CF-11-E

P2CF-11-E Summary of contents

Page 1

Digital Temperature Controllers/Digital Controllers E5@N/E5@N-H Upgraded 1/16, 1/8, and 1/4 DIN Controllers, the Best-selling E5@N Series. Basic Type (Renewal E5@N) and Advanced Type (New E5@N-H). • Improved indication accuracy and preventive maintenance (Basic Type E5@N). • New high-performance Controllers (Advanced ...

Page 2

Digital Temperature Controllers Digital Controllers Operation Procedure Common to All Controllers CX-Thermo Support Software 2 Contents E5CN/E5CN-U ............................................. E5AN/E5EN ................................................. E5CN-H........................................................ E5AN-H/E5EN-H.......................................... • Operation ..................................................... • Safety Precautions ....................................... • EST2-2C-MV4.............................................. ...

Page 3

... A PV/SV-status display function can be set to automatically alternate between displaying the status of the Temperature Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV. Preventive maintenance for relays in the Temperature Controller using a Control Output ON/OFF Counter. Main I/O Functions Event Inputs • None • ...

Page 4

E5CN/E5CN-U Lineup Terminal block E5CN Basic Type Plug-in Note: Models with one control output and one or two auxiliary outputs and models with two control outputs can be used for heating/cooling control. Model Number Structure Model Number Legend Controllers E5CN-@@M@@-@-500 ...

Page 5

Ordering Information Controllers with Terminal Blocks Power supply Size Case color voltage 100 to 240 VAC 24 VAC/VDC Black 1/16 DIN 100 to 240 VAC ( VAC/VDC 100 to 240 VAC Silver 24 VAC/VDC ...

Page 6

E5CN/E5CN-U Model Number Structure Model Number Legend (Plug-in-type Controllers) E5CN-@@@ Output Type R: Relay output Q: Voltage output (for driving SSR) C: Current output 2. Number of Alarms Blank: No alarm 1: One alarm 2: ...

Page 7

... E5B@. Sockets (for Plug-in Models) Front-connecting Socket Front-connecting Socket with Finger Protection Back-connecting Socket Terminal Cover for Back-connecting socket with Finger Protection CX-Thermo Support Software Model E54-CT1 E54-CT3 E5CN/E5CN-U Model Y92F-45 Type Model P2CF-11 P2CF-11-E P3GA-11 Y92A-48G Model EST2-2C-MV4 7 ...

Page 8

E5CN/E5CN-U Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 ...

Page 9

Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal Inputs) Input Platinum resistance Type thermometer Name Pt100 JPt100 K 2300 1800 1700 1600 1500 1400 1300 1300 1200 1100 1000 850 900 800 700 600 500.0 500.0 500.0 500 400 300 200 100.0 ...

Page 10

E5CN/E5CN-U Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also ...

Page 11

... When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s). ✽6. External communications (RS-485) and cable communications for the Setup Tool can be used at the same time. ✽7. The E5CN-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket. The P3GA-11 is not certified for UL listing. ...

Page 12

... ON, and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 100 50 ...

Page 13

... SSR) 12 VDC Current output DO NOT USE Load: 600 W max. Analog input Note: For the Wiring Socket, purchase the P2CF-11 or PG3A-11 separately. Auxiliary outputs (relay outputs) 250 VAC (resistive load) Auxiliary outputs (relay outputs) Control output 1 Auxiliary output 2 Auxiliary output 1 A ...

Page 14

E5CN/E5CN-U Nomenclature E5CN E5CN-U The front panel is the same for the E5CN and E5CN-U. Operation indicators Dimensions E5CN Terminal Models 48 48 E5CN-U Plug-in Models 48 48 Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 14 Temperature unit Level Key ...

Page 15

... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...

Page 16

... Front-connecting Socket Eleven, M3.5 P2CF-11 sems screws 70 max max. Note: A model with finger protection (P2CF-11-E) is also available. Back-connecting Socket P3GA-11 45 Note: 1. Using any other sockets will adversely affect accuracy. Use only the specified sockets Protective Cover for finger protection (Y92A-48G) is also available ...

Page 17

... A PV/SV-status display function can be set to automatically alternate between displaying the status of the Temperature Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV. Preventive maintenance for relays in the Temperature Controller using a Control Output ON/OFF Counter. Three-level display that simultaneously displays the PV, SV, and MV. ...

Page 18

E5AN/E5EN Lineup E5AN/E5EN Terminal block Basic Type Note: Models with one control output or two control outputs can be used for heating/cooling control. Model Number Structure Model Number Legend Controllers E5AN/E5EN-@3@M@@-@-500 Control ...

Page 19

Ordering Information E5AN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/4 DIN Analog ( (current/voltage) Thermocouple 24 VAC/ or VDC Resistance ...

Page 20

E5AN/E5EN E5EN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/8 DIN Analog (current/volt- age) Thermocouple 24 VAC/ or VDC Resistance ...

Page 21

Option Units Name Communications Unit Event Input Unit Accessories (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ1 Terminal Cover Connectable models E5AN E53-COV16 E5EN Note: The Terminal Cover comes with the E5CN-@@@-500 models. Waterproof Packing Connectable models E5AN E5EN Note: The ...

Page 22

E5AN/E5EN Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power 100 to ...

Page 23

Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal inputs) Input Platinum resistance type thermometer Name Pt100 JPt100 K 2300 1800 1700 1600 1500 1400 1300 1300 1200 1100 1000 850 900 800 700 600 500.0 500.0 500.0 500 400 300 200 100.0 ...

Page 24

E5AN/E5EN Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also ...

Page 25

Characteristics Thermocouple: ( 0.3% of indicated value whichever is greater) 1 digit max. ✽1 Platinum resistance thermometer: ( 0.2% of indicated value or 0.8 C, whichever is greater) 1 digit max. Indication accuracy Analog input: 0.2% FS ...

Page 26

... ON, and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 E5AN/E5EN 100 ...

Page 27

... The voltage output (control output 2, for driving SSR) has basic insulation provided for the internal circuit. Consult with your OMRON representative before using the external power supply for the ES1B for any other purpose. Controllers • ...

Page 28

E5AN/E5EN Nomenclature E5AN Temperature unit SUB1 SUB2 SUB3 Operation indicators HA OUT1 STOP OUT2 CMW MANU Programmable PF Function Key/ A/M Auto/Manual Key E5AN Level Key ✽ A 2-level display when shipped from the factory. A 3-level display is activated ...

Page 29

E5EN 48 96 Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 USB connector (type A plug) Terminal Covers E53-COV16 (Six Covers provided.) 6 79.2 2 112 91 Terminal Cover (E53-COV16) Waterproof Mounting Bracket (Accessory) Packing (Accessory) (Accessory) Crimp terminal size: M3.5 ...

Page 30

... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...

Page 31

... RUN/STOP, and alarms) and the PV or SV. Flexible contact outputs with logic operations (AND, OR, and delays) set from the Support Software (CX-Thermo Ver. 4.0) Preventive maintenance for relays in the Temperature Controller using a Control Output ON/OFF Counter. Main I/O Functions Event Inputs ...

Page 32

E5CN-H Lineup E5CN-H Terminal block Advanced Type Note: Models with one control output and models with two control outputs can be used for heating/cooling control. Model Number Structure Model Number Legend Controllers E5CN-@@@M@-@-500 ...

Page 33

Ordering Information Controllers Size Case Color Power supply voltage 100 to 240 VAC Black 24 VAC/VDC 1/16 DIN 100 to 240 VAC Silver 24 VAC/VDC Option Units One of the following Option Units can ...

Page 34

E5CN-H Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 ...

Page 35

Input Ranges Thermocouple/Platinum Resistance Thermometer/Analog Input (Fully Universal Inputs) Platinum resistance Input type thermometer Name Pt100 JPt100 2300 1800 1700 1600 1500 1400 1300.0 1300 1200 1100 1000 850.0 900 800 700 600 500.0 500.0 500.0 500 400 300 200.00 ...

Page 36

E5CN-H Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also ...

Page 37

Characteristics Thermocouple: ( 0.1% of indicated value whichever is greater) 1 digit max. ✽1 Platinum resistance thermometer: ( 0.1% of indicated value or 0.5 C, whichever is greater) 1 digit max. Indication accuracy Analog input: 0.1% FS ...

Page 38

... ON, and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 100 50 ...

Page 39

External Connections A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect any of the control output terminals to ground. If the control output terminals are ...

Page 40

E5CN-H Nomenclature E5CN-H Operation indicators Dimensions E5CN Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 40 Temperature unit SUB1 SUB2 SUB3 HA OUT1 STOP OUT2 CWM MANU Level Key E5CN-H Mode Key Down Key 1.5 58 ...

Page 41

... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...

Page 42

E5CN-H Adapter Y92F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@. Mounted to E5CN-H 42 4.7 76 69 Panel ( mm 2.2 4.7 77.3 ...

Page 43

... Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV. Flexible contact outputs with logic operations (AND, OR, and delays) set from the Support Software (CX-Thermo Ver. 4.0) Preventive maintenance for relays in the Temperature Controller using a Control Output ON/OFF Counter. Model available with position-proportional control Main I/O Functions ...

Page 44

E5AN-H/E5EN-H Lineup E5AN-H/E5EN-H Terminal block Advanced Type Note: The Controller can be used for heating/cooling control even if only 1 control output is used. Model Number Structure Model Number Legend Controllers E5AN/E5EN-@@@@@@@M@-@-500 ...

Page 45

Ordering Information E5AN-H Power Case Control Auxiliary Size supply color method output voltage 2 Basic 100 to 240 VAC 3 Valve 2 Black 1/4 DIN Basic 24 VAC/ VDC 3 Valve 2 100 ...

Page 46

E5AN-H/E5EN-H E5EN-H Power Case Control Size supply color method voltage Basic 100 to 240 VAC Valve Black 1/8 DIN Basic 24 VAC/ VDC Valve 100 to 240 VAC Silver Basic 24 VAC/ VDC Accessories ...

Page 47

Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 VAC: ...

Page 48

E5AN-H/E5EN-H Input Ranges Thermocouple/Platinum Resistance Thermometer (Fully Universal Inputs) Input Platinum resistance type thermometer Name Pt100 JPt100 2300 1800 1700 1600 1500 1400 1300.0 1300 1200 1100 1000 850.0 900 800 700 600 500.0 500.0 500 400 300 200.00 200 ...

Page 49

Alarm Outputs Each alarm can be independently set to one of the following 15 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be ...

Page 50

E5AN-H/E5EN-H Characteristics Thermocouple: ( 0.1% of indicated value whichever is greater) 1 digit max. ✽1 Platinum resistance thermometer: ( 0.1% of indicated value or 0.5 C, whichever is greater) 1 digit max. Indication accuracy Analog input: 0.1% ...

Page 51

USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version Applicable software 4.0 or higher E5AN/E5EN/E5CN/E5CN-U/ Applicable models E5AN-H/E5EN-H/E5CN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A plug) ...

Page 52

... E5AN-H/E5EN-H Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 E5AN-H/E5EN-H 100 250 VAC, 30 VDC (resistive load) cos = Switching current (A) 52 SSR Outputs (OUT1/OUT2) Ratings Rated load voltage 250 VAC Rated load current (resistive load) Note: 1. The load current must be within the derating curve. ...

Page 53

External Connections A voltage output (control output 1, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect any of the control output terminals to ground. If the control output terminals ...

Page 54

E5AN-H/E5EN-H Nomenclature E5AN-H Temperature unit SUB1 SUB2 SUB3 Operation indicators HA OUT1 RSP STOP OUT2 CMW MANU Programmable PF Function Key/ A/M Auto/Manual Key E5AN-H Level Key Dimensions E5AN 112 Waterproof Packing (Accessory) 54 E5EN-H Operation indicators PV ...

Page 55

E5EN 112 96 Waterproof Mounting Bracket Packing (Accessory) (Accessory) Mounted Separately +0 120 min. ✽ Group mounting is not possible if an SSR output is used for control output and the ...

Page 56

E5AN-H/E5EN-H Accessories (Order Separately) USB-Infrared Conversion Cable E58-CIFIR USB-Infrared Conversion Cable USB connector (type A plug) Mounting Adapter USB-Serial Conversion Cable E58-CIFQ1 Terminal Covers E53-COV16 (Six Covers provided.) 56 (2,000) With Mounting Adapter Connected 39 16 18.5 Mounting Adapter (Accessory) ...

Page 57

... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...

Page 58

E5@N/E5@N-H Operation Setting Levels Diagram This diagram shows all of the setting levels. To move to the advanced function setting level and calibration level, you must enter passwords. Some parameters are not displayed depending on the protect level setting and ...

Page 59

Advanced Type Start in manual mode. Start in automatic mode. Press the O Key or the PF Key for at least 1 s. ✽4 a-m Press the O Key for at least 3 s while a-m is displayed. (a-m will ...

Page 60

E5@N/E5@N-H Parameters Basic Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156). Press the PF Key for ...

Page 61

Monitor/Setting Item Level 25 C Monitor/Setting PF Item Display 1 0 Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item parameters (advanced function setting level). Press the O Key for at least 1 ...

Page 62

E5@N/E5@N-H Advanced Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN-H/E5AN-H/ E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). Protect Level PID Setting Level Display ...

Page 63

Press the PF Key for at least 1 s. ✽1 Press the O Key less than 1 s. Adjustment Level Adjustment Level Display l.adj Displayed only p c once when Proportional Band 8.0 entering adjustment level ...

Page 64

E5@N/E5@N-H Press the O Key for at least 1 s. Press the O Key for at least 3 s. Other than the Auto/Manual Switch display Protect Level The time taken to move to the protect level can be adjusted by ...

Page 65

Power ON Manual Control Level Operation Adjustment Protect Level Level Level Communica- Initial Setting tions Setting Level Level Advanced Function Setting Level Press the O Key for at least 1 s. Advanced Function Setting Level init o-dp MV Display Parameter ...

Page 66

... Caution: To reduce the risk of fire or electric shock, do not interconnect the outputs of different Class 2 circuits. ✽2 If the output relays are used past their life expectancy, contact fusing or burning may occasionally occur. Always consider the application conditions and use the output relays within their rated load and electrical life expectancy ...

Page 67

ON power to the load (e.g., heater) at the same time as or before supplying power to the product. If power is turned ON to the product before turning ON power to the load, self-tuning will ...

Page 68

... For waterproof mounting, waterproof packing must be installed on the Controller. Waterproofing is not possible when group mounting several Controllers. Waterproof packing is not necessary when there is no need for the waterproofing function. E5CN Order the P2CF-11 or P3GA-11 Socket separately. E53-COV17 Terminal Cover (Accessory) Adapter ...

Page 69

E5AN/E5EN Tool insertion hole (1) (2) (3) E5AN (1) 1. Insert a flat-blade screwdriver into the two tool insertion holes (one on the top and one on the bottom) to release the hooks. 2. Insert the flat-blade screwdriver in the ...

Page 70

CX-Thermo Support Software Ver. 4.0 EST2-2C-MV4 Monitoring/Setting Support Software for E5CN/CN-H, E5AN/AN-H, E5EN/EN-H, E5ZN, E5@R/@R-T, and EJ1 Temperature Controllers Enabling Faster Parameter Setup, Device Adjustment, and Maintenance Enables editing and batch-downloading parameters from a personal computer, reducing the work required ...

Page 71

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 72

... OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • ...

Related keywords