P2CF-11-E Omron, P2CF-11-E Datasheet - Page 59

no-image

P2CF-11-E

Manufacturer Part Number
P2CF-11-E
Description
SOCKET 11-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr
Series
-r
Datasheets

Specifications of P2CF-11-E

Number Of Positions
11
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Features
-
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
11
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
For Use With/related Products
Multiple Series
For Use With
Z2998 - RELAY TIMER DGTL SPDT 100/240VACZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF11E
Advanced Type
✽1. You can return to the operation level by executing a software reset.
✽2. It is not possible to move to other levels from the calibration level by operating the keys on the front panel.
✽3. From the manual control level, key operations can be used to move to the operation level only.
✽4. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN-H/E5EN-H).
✽5. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN-H/E5EN-H)
Error Displays (Troubleshooting)
When an error occurs, the No.1 display shows the error code. Take necessary measure according to the error code, referring the table below.
Note: If the input value exceeds the display limit ( 19999 to 32400), though it is within the control range,
✽ These errors are displayed only when the PV/SP is displayed. Errors are not displayed for other displays.
s.err
e333
e111
Manual
mode
No.1 display
It can be done only by first turning OFF the power.
and
For details on the control range, refer to the E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157).
(E333)
(E111)
(S. Err)
Manual
Control Level
Start in manual mode.
Press the O Key or the
PF Key for at least 1 s. ✽4
✽3
above 32400. Under these conditions, control output and alarm output will operate normally.
Input error
A/D
converter
error
Memory
error
Meaning
a-m
Press the O Key
for at least 3 s while
a-m is displayed.
(a-m will flash after
1st second.)
Control stops.
Start in automatic mode.
Press the PF Key
for at least 1 s.
Check the wiring of inputs for miswiring, disconnections, and short-circuits and check the
input type.
Turn the power OFF then back ON again. If the display remains the same, the controller must
be repaired. If the display is restored to normal, then a probable cause can be external noise
affecting the control system. Check for external noise.
Turn the power OFF then back ON again. If the display remains the same, the controller must
be repaired. If the display is restored to normal, then a probable cause can be external noise
affecting the control system. Check for external noise.
Press the O Key
for at least 1 s.
Press the O Key
for at least 1 s.
✽4
✽1
Operation
Level
Power ON
Initial Setting
Level
Advanced Function
Setting Level
PF Key
✽5
PID Setting
Level
Calibration Level
Press the
O Key less than 1 s.
Press the
O Key less than 1 s.
Monitor/Setting
Item Level
Input password.
Action
Input password while
amov is displayed.
(Set value 169)
Press the
O Key for less than 1 s.
c
Press the
O Key less
than 1 s.
25.0
100.0
✽2
Press the O Key for at
least 3 s. (Display will flash
after 1st second.)
Communica-
tions Setting
Level
Bank Setting
Level
Adjustment
Level
PF Key
Press the
O Key less
than 1 s.
✽5
Control in progress
Control stopped
Not displayed for some models
Level change
Press
the O +
M Keys
for at
least 3 s.
(Display
will flash
after 1st
second.)
Note: The time taken to
Control output
c
will be displayed under 19999
E5@N/E5@N-H
25.0
move to the protect
level can be adjusted
by changing the
“Move to protect level
time” setting.
Protect Level
100.0
OFF
OFF
OFF
Status at error
Operates as above
Press the O+
M Keys for at
least 1 s.
the upper limit.
Alarm output
OFF
OFF
59