P2CF-11-E Omron, P2CF-11-E Datasheet - Page 50

no-image

P2CF-11-E

Manufacturer Part Number
P2CF-11-E
Description
SOCKET 11-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr
Series
-r
Datasheets

Specifications of P2CF-11-E

Number Of Positions
11
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Features
-
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
11
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
For Use With/related Products
Multiple Series
For Use With
Z2998 - RELAY TIMER DGTL SPDT 100/240VACZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF11E
50
E5AN-H/E5EN-H
Characteristics
✽1. The indication accuracy of K thermocouples in the 200 to 1300 C range, T and N thermocouples at a temperature of
✽2. Ambient temperature: 10 C to 23 C to 55 C, Voltage range: 15% to 10% of rated voltage
✽3. K thermocouple at 100 C max.: 10 C max.
✽4. External communications (RS-232C, RS-485, or RS-422) and cable communications for the Setup Tool can be used at the same time.
Indication accuracy
Transfer output accuracy
Influence of temperature
✽2
Influence of voltage ✽2
Input sampling period
Hysteresis
Proportional band (P)
Integral time (I)
Derivative time (D)
Control period
Manual reset value
Alarm setting range
Affect of signal source
resistance
Insulation resistance
Dielectric strength
Vibration
resistance
Shock
resistance
Weight
Degree of protection
Memory protection
Setup Tool
Setup Tool port
Standards
EMC
temperature of 400 C max. is not specified. The indication accuracy of B thermocouples in the 400 to 800 C range is 3 C max. The indication
accuracy of the R and S thermocouples at a temperature of 200 C max. is 3 C 1 digit max. The indication accuracy of W thermocouples is
The indication accuracy of PL II thermocouples is 0.3% of PV or 2 C, whichever is greater, 1 digit max.
100 C max., and U and L thermocouples at any temperatures is 2 C 1 digit max. The indication accuracy of the B thermocouple at a
0.3% of PV or 3 C, whichever is greater, 1 digit max.
Malfunction 10 to 55 Hz, 20 m/s
Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions
Malfunction 100 m/s
Destruction 300 m/s
E5AN-H
E5EN-H
Approved
standards
Conformed
standards
Thermocouple: ( 0.1% of indicated value or 1 C, whichever is greater) 1 digit max. ✽1
Platinum resistance thermometer: ( 0.1% of indicated value or 0.5 C, whichever is greater) 1 digit max.
Analog input: 0.1% FS 1 digit max.
CT input: 5% FS 1 digit max.
Potentiometer input: ±5% FS ±1 digit max.
Thermocouple input (R, S, B, W, PL II): ( 1% of PV or 10 C, whichever is greater) 1 digit max.
Other thermocouple input: ( 1% of PV or 4 C, whichever is greater) 1 digit max. ✽3
Platinum resistance thermometer: ( 1% of PV or 2 C, whichever is greater) 1 digit max.
Analog input: ( 1%FS) 1 digit max.
60 ms
Temperature input: 0.1 to 3240.0 C or F (in units of 0.1 C or F)
Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)
Temperature input: 0.1 to 3240.0 C or F (in units of 0.1 C or F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
0.0 to 3240.0 s (in units of 0.1 s)
0.0 to 3240.0 s (in units of 0.1 s)
0.5, 1 to 99 s (in units of 1 s)
0.0 to 100.0% (in units of 0.1%)
Thermocouple: 0.1 C/
Platinum resistance thermometer: 0.1 C/
20 M min. (at 500 VDC)
2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)
Controller: Approx. 310 g, Mounting Bracket: Approx. 100 g
Controller: Approx. 260 g, Mounting Bracket: Approx. 100 g
Front panel: IP66, Rear case: IP20, Terminals: IP00
Non-volatile memory (number of writes: 1,000,000 times)
CX-Thermo version 4.0 or higher
Provided on the bottom of the E5AN-H and E5EN-H.
An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5AN-H and E5EN-H.
Provided on the front of the E5AN-H and E5EN-H. An E58-CIFIR USB-infrared Conversion Cable is required to
connect the computer to the E5AN-H or E5EN-H. ✽4
UL 61010-1, CSA C22.2 No. 1010-1
EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II
EMI:
Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A
Noise Terminal Voltage:
EMS:
ESD Immunity:
Electromagnetic Field Immunity:
Burst Noise Immunity:
Conducted Disturbance Immunity:
Surge Immunity:
Power Frequency Magnetic Field Immunity:
Voltage Dip/Interrupting Immunity:
0.3% FS max.
19999 to 32400 (decimal point position depends on input type)
2
2
, 3 times each in X, Y, and Z directions
, 3 times each in X, Y, and Z directions
2
for 10 min each in X, Y, and Z directions
max. (100
max.)
max. (10
EN 61326
EN 55011 Group 1, class A
EN 61326
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
max.)
EN 61000-4-5

Related parts for P2CF-11-E