H3CR-F AC100-240 Omron, H3CR-F AC100-240 Datasheet - Page 17

RELAY REPEAT CYCLE ANLG 30HRS

H3CR-F AC100-240

Manufacturer Part Number
H3CR-F AC100-240
Description
RELAY REPEAT CYCLE ANLG 30HRS
Manufacturer
Omron
Series
H3CR-Fr
Datasheets

Specifications of H3CR-F AC100-240

Mounting Type
Socket
Relay Type
Integrated
Function
Repeat Cycle
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 30 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Timing Range
0.05 s to 30 Hrs
Supply Voltage
100 V to 240 V
Time Range
0.05 Sec. To 30 Hr.
Supply Voltage Ac, Min
100VAC
No. Of Timing Functions
2
Body Material
38B610
No. Of Pins
11
Supply Voltage Ac, Max
240VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H3CR-F-AC100-240
H3CR-F-AC100-240
H3CRFAC100240
Q2238220
Z2366
2. Signal Start/Signal Reset (in B Mode)
If there is an abnormal signal, flashing starts. When the abnormal
condition is restored, a reset signal stops the display flashing.
C Mode: Signal ON/OFF-delay
The Signal ON-/OFF-delay operation (C mode) is useful for the
control of distribution of products on a production line into boxes by
the specified number or time.
1. Power-ON Start/Instantaneous Operation/
A set of these functions is useful for the operation of a machine for a
specified period when power is ON.
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Time-limit Reset
Power (2 and 10)
Power (2 and 10)
Reset (2 and 7)
Power indicator
Start (2 and 6)
Start (2 and 6)
NC (1 and 4)
NO (1 and 3)
NC (1 and 4)
NO (1 and 3)
Externally short-circuited
Start signal
Reset signal
Lit
(Power continuously supplied)
Power
supply
Power
supply
Flashing
t
t
Lit
2. Signal-ON-OFF Start/Instantaneous
D Mode: Signal OFF-delay
Signal OFF-delay operation (D mode) can be effectively used to keep
a load operating for a certain period. For example, this function
enables the cooling fan for a lamp or heater to operate for a certain
period after the lamp or heater is switched OFF.
1. Power-ON Start/Instantaneous Operation/
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Operation/Time-limit Reset
Time-limit Reset
Power (2 and 10)
Power (2 and 10)
Power indicator
Power indicator
Start (2 and 6)
Start (2 and 6)
NC (1 and 4)
NO (1 and 3)
NC (1 and 4)
NO (1 and 3)
Start signal (NC to NO)
Start signal
(The operation starts with the signal ON or OFF)
(Power continuously supplied)
Lit
Power
supply
Power
supply
Flashing
H3CR-A
Lit
17