H3CR-F AC100-240 Omron, H3CR-F AC100-240 Datasheet - Page 26

RELAY REPEAT CYCLE ANLG 30HRS

H3CR-F AC100-240

Manufacturer Part Number
H3CR-F AC100-240
Description
RELAY REPEAT CYCLE ANLG 30HRS
Manufacturer
Omron
Series
H3CR-Fr
Datasheets

Specifications of H3CR-F AC100-240

Mounting Type
Socket
Relay Type
Integrated
Function
Repeat Cycle
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 30 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Timing Range
0.05 s to 30 Hrs
Supply Voltage
100 V to 240 V
Time Range
0.05 Sec. To 30 Hr.
Supply Voltage Ac, Min
100VAC
No. Of Timing Functions
2
Body Material
38B610
No. Of Pins
11
Supply Voltage Ac, Max
240VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H3CR-F-AC100-240
H3CR-F-AC100-240
H3CRFAC100240
Q2238220
Z2366
Protective Cover
Y92A-48B
The protective cover protects the front panel, particularly the time
setting section, against dust, dirt, and water. It also prevents the set
value from being altered due to accidental contact with the time
setting knob.
Note: 1. The Y92A-48B Protective Cover is made of a hard plastic
Time Setting Ring/Panel Cover for H3CR-A/-G
There are three types of Panel Covers (Y92P-48GL, Y92P-48GB,
and Y92P-48GM), all of which are available in three colors. Use the
most suitable type of Panel Cover with the design of the scaling plate
according to the application.
When setting a given time for the Timer, use of the Y92S-27 or
Y92S-28 Time Setting Ring facilitates the time setting operation and
minimizes possible setting errors by operators.
The Y92F-73 or Y92-F-74 Flush Mounting Adapter or the Protective
Cover cannot be used.
2. The Protective Cover cannot be mounted if the Panel Cover
Y92S-27
Time Setting A
and therefore it must be removed to change the timer set
value.
(sold separately) is used on the Timer.
Y92A-48B
Y92S-28
Time Setting B
Y92S-28
Time Setting C
Y92P-48GL
Light Gray
Hold-down Clip
Hold-down clips are sold in sets of two.
The Time Setting Ring and Panel Cover should be used as a pair.
Y92H-7/-1
For PL08 and PL11 Sockets
Setting a specific
time
Limiting the setting
range
Y92P-48GB
Black
Time Setting Ring A (Y92S-27) and Panel
Cover (Y92P-48GL, -48GB, or -48GM)
Time Setting Ring B or C (Y92S-28), and
Panel Cover (Y92P-48GL, -48GB, or -48GM)
Y92P-48GM
Medium Gray
Y92H-8/-2
For PF085A Socket
H3CR
6

Related parts for H3CR-F AC100-240