H3CR-F AC100-240 Omron, H3CR-F AC100-240 Datasheet - Page 3

RELAY REPEAT CYCLE ANLG 30HRS

H3CR-F AC100-240

Manufacturer Part Number
H3CR-F AC100-240
Description
RELAY REPEAT CYCLE ANLG 30HRS
Manufacturer
Omron
Series
H3CR-Fr
Datasheets

Specifications of H3CR-F AC100-240

Mounting Type
Socket
Relay Type
Integrated
Function
Repeat Cycle
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 30 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Timing Range
0.05 s to 30 Hrs
Supply Voltage
100 V to 240 V
Time Range
0.05 Sec. To 30 Hr.
Supply Voltage Ac, Min
100VAC
No. Of Timing Functions
2
Body Material
38B610
No. Of Pins
11
Supply Voltage Ac, Max
240VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H3CR-F-AC100-240
H3CR-F-AC100-240
H3CRFAC100240
Q2238220
Z2366
■ Accessories (Order Separately)
Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 or P3GA-11 Socket.
Specifications
■ General
*The internal circuits are optically isolated from the output. This enables universal application as NPN or PNP transistor.
Operating mode
Pin type
Input type
Time-limit output type
Instantaneous output type ---
Mounting method
Approved standards
Flush Mounting Adapter
Mounting Track
End Plate
Spacer
Protective Cover
Track Mounting/
Front Connecting Socket
Back Connecting Socket
Time Setting Ring (See note 2)
Panel Cover
Hold-down Clip (See note 3)
2. The Time Setting Ring cannot be used alone. It must be used together with the Panel Cover.
3. Hold-down Clips are sold in sets of two.
Item
A: ON-delay
B: Flicker OFF start
B2: Flicker ON start
C: Signal ON/OFF-delay
D: Signal OFF-delay
E: Interval
G: Signal ON/OFF-delay (Only for H3CR-A-300)
J: One-shot (Only for H3CR-A-300)
11-pin
No-voltage input
H3CR-A/-A8/-AP: Relay output (DPDT)
H3CR-AS/-A8S: Transistor output (NPN/PNP universal)*
DIN track mounting, surface mounting, and flush mounting
UL508, CSA C22.2 No.14, NK, Lloyds
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1 for Timers with Contact Outputs.
Output category according to EN60947-5-2 for Timers with Transistor Outputs.
Name/specifications
H3CR-A/-AS
50 cm (l) × 7.3 mm (t)
1 m (l) × 7.3 mm (t)
1 m (l) × 16 mm (t)
8-pin
8-pin, finger safe type
11-pin
11-pin, finger safe type
8-pin
8-pin, finger safe type
11-pin
11-pin, finger safe type
Setting a specific time
Limiting the setting range
Light gray (5Y7/1)
Black (N1.5)
Medium gray (5Y5/1)
For PL08 and PL11 Sockets
For PF085A Socket
Voltage input
H3CR-AP
Y92F-30
Y92F-73
Y92F-74
PFP-50N
PFP-100N
PFP-100N2
PFP-M
PFP-S
Y92A-48B
P2CF-08
P2CF-08-E
P2CF-11
P2CF-11-E
P3G-08
P3G-08 with Y92A-48G (See note 1)
P3GA-11
P3GA-11 with Y92A-48G (See note 1)
Y92S-27
Y92S-28
Y92P-48GL
Y92P-48GB
Y92P-48GM
Y92H-7
Y92H-8
A: ON-delay (power supply start)
B2: Flicker ON start (power supply start)
E: Interval (power supply start)
J: One-shot (power supply start)
8-pin
---
H3CR-A8/-A8S
Models
Relay output (SPDT)
Relay output (SPDT)
H3CR-A8E
H3CR-A
3

Related parts for H3CR-F AC100-240