H5CX-ASD-N-DC12-24/AC24 Omron, H5CX-ASD-N-DC12-24/AC24 Datasheet - Page 38

RELAY TIMER DGTL TRANS 12-24VDC

H5CX-ASD-N-DC12-24/AC24

Manufacturer Part Number
H5CX-ASD-N-DC12-24/AC24
Description
RELAY TIMER DGTL TRANS 12-24VDC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-ASD-N-DC12-24/AC24

Relay Type
Integrated
Function
Programmable (Multi-Function)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Transistor
Voltage - Supply
12 ~ 24VDC, 24VAC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Timing Range
0.001 s to 9999 Hrs
Supply Voltage
12 V to 24 V
Current Rating (max)
100 mA
Display Type
4 Digit LCD Backlight
Product
Digital Timer
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Circuit
-
Contact Rating @ Voltage
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
H5CXASDNDC1224AC24
Z3001
■ Characteristics
Note 1. The values are based on the set value.
■ Inrush Current (Reference Values)
Accuracy of operating time
and setting error (including
temperature and voltage in-
fluences) (See note 1.)
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Approved safety
standards (See note 2.)
EMC
Degree of protection
Weight
12 to 24 VDC 26.4 VDC
Voltage
2. The Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter are necessary to ensure IP66, NEMA4, and UL Type 4X water-
proofing between the H5CX and installation panel.
Item
Applied voltage
Power-ON start: ±0.02% ±0.05 s max. Rated against set value
Signal start (minimum pulse width of 20 ms): ±0.01% ±0.03 s max. Rated against set value
Signal start (minimum pulse width of 1 ms): ±0.01% ±3 ms max.
If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the
sensor waiting time passes.
100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
1,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuit
1.0 kV (between power terminals)
1.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
±480 V (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator
(pulse width: 100 ns/1 µs, 1-ns rise)
Destruction: 15 kV
Malfunction: 8 kV
Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions, 2 hours each
Malfunction: 10 to 55 Hz with 0.35-mm single amplitude each in three directions, 10 min each
Destruction: 294 m/s
Malfunction: 196 m/s
UL508/Listing, UL50 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14, conforms to EN61812-1 (Pollution
degree 2/overvoltage category III)
Conforms to VDE0106/P100 (finger protection).
(EMI)
Emission Enclosure:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted
Disturbance:
Immunity Burst:
Immunity Surge:
Panel surface: IP66 and NEMA4 (indoors), and UL Type 4X (indoors) (See note 2.)
Approx. 140 g
6 A
Inrush current
(peak value)
2
2
each in three directions
each in three directions
1.2 ms
EN61812-1
EN55011 Group 1 class A
EN61812-1
EN61000-4-2:
EN61000-4-3:
EN61000-4-6:
EN61000-4-4:
EN61000-4-5:
Time
H5CX-BWSD
6 kV contact discharge (level 2)
8 kV air discharge (level 3)
10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3);
1 kV I/O signal-line (level 4)
1 kV line to lines (power and output lines) (level 3);
2 kV line to ground (power and output lines) (level 3)
H5CX-B
38

Related parts for H5CX-ASD-N-DC12-24/AC24