K-HSTTA Panduit Corp, K-HSTTA Datasheet - Page 52

no-image

K-HSTTA

Manufacturer Part Number
K-HSTTA
Description
KIT HT SHRINK ADH 3/16"-1" BLK
Manufacturer
Panduit Corp
Datasheet
Flammability Tests and Classifications
Materials classified 94V-1 shall:
• Not have a total flaming combustion time exceeding 250 seconds for the 10 flame applications for each
• Not have any specimens which burn with flaming or glowing combustion up to the holding clamp.
• Not have any specimens which drip flaming par ticles that ignite the dry absorbent surgical cotton located
• Not have an specimens with glowing combustion which persists for more than 60 seconds after the
Materials classified 94V-2 shall:
• Not have any specimens which burn with flaming combustion for more than 30 seconds after either
• Not have a total flaming combustion time exceeding 250 seconds for the 10 flame applications for each set
• Not have any specimens which burn with flaming or glowing combustion up to the holding clamp.
• Be permitted to have specimens which drip flaming particles which burn only briefly some of which ignite
• Not have any specimens with glowing combustion which persists for more than 60 seconds after the
• Specimens shall have a maximum burn rate of 1.5 in./min over 3 inches of thickness of 0.120" to 0.5".
• Specimens shall have a maximum burn rate of 2.5 in./min over 3 inches for a thickness less than 0.120".
Samples of fully recovered tubing are placed over a length of fine spring steel music wire. The test requires
the precise placement of a controlled flame that contacts the heat shrink tubing. The flame is applied in five
fifteen second intervals with a time period between applications. If the flame extinguishes immediately after
the first flame removal, subsequent flame applications are made to the tubing. Duration of specimen flaming
is noted. A piece of surgical cotton is placed under the specimen. If a flaming or glowing piece of tubing
drips and ignites the cotton, this is also noted.
• Not flame or glow longer than 60 seconds following any of the five applications of the flame.
• Not ignite or damage more than 25% of kraft paper flag that is placed around the top of the tubing.
• Not have any specimens which drip flaming par ticles and ignite the surgical cotton located 9 1/2 inches
52
set of five specimens.
12"(305mm) below the test specimen.
second removal of the test flame.
application of the test flame.
of five specimens.
the dry absorbent surgical cotton located 12" (305mm) below the test specimen.
second removal of the test flame.
below the test specimen.
MATERIALS CLASSIFIED AS VW-1 SHALL:
UL224 VERTICAL WIRE FLAME TEST
MATERIALS CLASSIFIED UL-94 HB
MATERIALS CLASSIFIED 94V-1
MATERIALS CLASSIFIED 94V-2