PIC18LF6310-I/PT Microchip Technology, PIC18LF6310-I/PT Datasheet - Page 18

IC PIC MCU FLASH 4KX16 64TQFP

PIC18LF6310-I/PT

Manufacturer Part Number
PIC18LF6310-I/PT
Description
IC PIC MCU FLASH 4KX16 64TQFP
Manufacturer
Microchip Technology
Series
PIC® 18Fr

Specifications of PIC18LF6310-I/PT

Core Size
8-Bit
Program Memory Size
8KB (4K x 16)
Oscillator Type
Internal
Core Processor
PIC
Speed
40MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, HLVD, POR, PWM, WDT
Number Of I /o
54
Program Memory Type
FLASH
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 5.5 V
Data Converters
A/D 12x10b
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TFQFP
Controller Family/series
PIC18
No. Of I/o's
54
Ram Memory Size
768Byte
Cpu Speed
40MHz
No. Of Timers
4
No. Of Pwm
RoHS Compliant
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18LF6310-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
PIC18F8410/8490/8493 FAMILY
4.2
The verify step involves reading back the code memory
space and comparing it against the copy held in the
programmer’s buffer. Memory reads occur a single byte
at a time, so two bytes must be read to compare
against the word in the programmer’s buffer. Refer to
Section 4.1 “Read Code Memory, ID Locations and
Configuration Bits” for implementation details of
reading code memory.
The Table Pointer must be manually set to 200000h
(base address of the ID locations) once the code
memory has been verified. The post-increment feature
of the table read 4-bit command may not be used to
increment the Table Pointer to 200000h. After setting
the Table Pointer to 200000h, the post-increment
feature may be used to increment to 200001h,
200002h and so on.
FIGURE 4-2:
DS39624C-page 18
Verify Code Memory and ID
Locations
No
Read High Byte
Read Low Byte
Set Pointer = 0
Word = Expect
Code Memory
VERIFY CODE MEMORY AND ID LOCATIONS FLOW
Verified?
Data?
Does
Start
All
Yes
Yes
No
Failure,
Report
Error
4.3
A configuration address may be read and output on
PGD via the 4-bit command, 1001. Configuration data
is read and written in a byte-wise fashion, so it is not
necessary to merge two bytes into a word prior to a
compare.
compared to the appropriate configuration data in the
programmer’s memory for verification. Refer to
Section 4.1 “Read Code Memory, ID Locations and
Configuration Bits” for implementation details of
reading configuration data.
No
Verify Configuration Bits
Set Pointer = 200000h
Read High Byte
Read Low Byte
Word = Expect
The result may then be immediately
ID Locations
Verified?
Data?
Does
Done
All
Yes
Yes
© 2007 Microchip Technology Inc.
No
Failure,
Report
Error

Related parts for PIC18LF6310-I/PT