AT32UC3L064-D3HR Atmel, AT32UC3L064-D3HR Datasheet - Page 99

no-image

AT32UC3L064-D3HR

Manufacturer Part Number
AT32UC3L064-D3HR
Description
MCU AVR32 64K FLASH 48TTLGA
Manufacturer
Atmel
Series
AVR®32 UC3r
Datasheet

Specifications of AT32UC3L064-D3HR

Core Processor
AVR
Core Size
32-Bit
Speed
50MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, PWM, WDT
Number Of I /o
36
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.62 V ~ 3.6 V
Data Converters
A/D 9x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3L064-D3HR
Manufacturer:
ATMEL
Quantity:
134
Part Number:
AT32UC3L064-D3HR
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
10.4.15
10.4.16
32099F–11/2010
PWMA
TC
1. PARAMETER register reads 0x2424
2. Open drain mode does not work
3. VERSION register reads 0x100
4. Writing to the duty cycle registers when the timebase counter overflows can give an
5. BUSY bit is never cleared after writes to the Control Register (CR)
6. Incoming peripheral events are discarded during duty cycle register update
1. When the main clock is RCSYS, TIMER_CLOCK5 is equal to CLK_PBA
Use an external inverter to invert the signal going into the TWIM. When using both TWIM
and TWIS on the same pins, the SMBAL cannot be used.
The PARAMETER register reads 0x2424 instead of 0x24.
Fix/Workaround
None.
The open drain mode does not work.
Fix/Workaround
None.
The VERSION register reads 0x100 instead of 0x101.
Fix/Workaround
None.
undefined result
The duty cycle registers will be corrupted if written when the timebase counter overflows. If
the duty cycle registers are written exactly when the timebase counter overflows at TOP, the
duty cycle registers may become corrupted.
Fix/Workaround
Write to the duty cycle registers only directly after the Timebase Overflow bit in the status
register is set.
When writing a non-zero value to CR.TOP, CR.SPREAD, or CR.TCLR when the PWMA is
disabled (CR.EN==0), the BUSY bit in the Status Register (SR.BUSY) will be set, but never
cleared.
Fix/Workaround
When writing a non-zero value to CR.TOP, CR.SPREAD, or CR.TCLR, make sure the
PWMA is enabled, or simultaneously enable the PWMA by writing a one to CR.EN.
Incoming peripheral events to all applied channels will be discarded if a duty cycle update is
received from the user interface in the same PWMA clock period.
Fix/Workaround
Ensure that duty cycle writes from the user interface are not performed in a PWMA clock
period when an incoming peripheral event is expected.
When the main clock is generated from RCSYS, TIMER_CLOCK5 is equal to CLK_PBA and
not CLK_PBA/128.
Fix/Workaround
None.
AT32UC3L016/32/64
99