Z8F3222VS020SG Zilog, Z8F3222VS020SG Datasheet - Page 177

IC ENCORE MCU FLASH 32K 68PLCC

Z8F3222VS020SG

Manufacturer Part Number
Z8F3222VS020SG
Description
IC ENCORE MCU FLASH 32K 68PLCC
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheets

Specifications of Z8F3222VS020SG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
46
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
68-LCC (J-Lead)
Processor Series
Z8F322x
Core
eZ8
Data Bus Width
8 bit
Data Ram Size
2 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
46
Number Of Timers
4
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 12 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
269-4263
Z8F3222VS020SG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8F3222VS020SG
Manufacturer:
Zilog
Quantity:
69
Part Number:
Z8F3222VS020SG
Manufacturer:
Zilog
Quantity:
10 000
DMA Control Register Definitions
Table 77. DMAx Control Register (DMAxCTL)
PS019921-0308
BITS
FIELD
RESET
R/W
ADDR
Caution:
DMAx Control Register
DEN
7
The DMAx Control register (see
operation for DMAx.
DEN—DMAx Enable
0 = DMAx is disabled and data transfer requests are disregarded.
1 = DMAx is enabled and initiates a data transfer upon receipt of a request from the
DLE—DMAx Loop Enable
0 = DMAx reloads the original Start Address and is then disabled after the End
Address data is transferred.
When using the DMA_ADC to perform conversions on multiple ADC inputs,
the Analog-to-Digital Converter must be configured for SINGLE-SHOT mode.
If the ADC_IN field in the DMA_ADC Control Register is greater than 000b,
the ADC must be in SINGLE-SHOT mode.
CONTINUOUS mode operation of the ADC can only be used in conjunction
with DMA_ADC if the ADC_IN field in the DMA_ADC Control Register is re-
set to 000b to enable conversion on ADC Analog Input 0 only.
trigger source.
Enable the DMA_ADC interrupt request, if desired
Select the number of ADC Analog Inputs to convert
Enable the DMA_ADC channel
DLE
6
DDIR
5
IRQEN
Table 77
4
FB0H, FB8H
R/W
0
on page 163) enables and selects the mode of
WSEL
3
Z8 Encore! XP
2
Direct Memory Access Controller
Product Specification
RSS
1
®
F64XX Series
0
163

Related parts for Z8F3222VS020SG