Z8F4823FT020SG Zilog, Z8F4823FT020SG Datasheet

IC ENCORE MCU FLASH 48K 80QFP

Z8F4823FT020SG

Manufacturer Part Number
Z8F4823FT020SG
Description
IC ENCORE MCU FLASH 48K 80QFP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheets

Specifications of Z8F4823FT020SG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
60
Program Memory Size
48KB (48K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
80-BQFP
Processor Series
Z8F482x
Core
eZ8
Data Bus Width
8 bit
Data Ram Size
4 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
60
Number Of Timers
4
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 12 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
269-4275
Z8F4823FT020SG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8F4823FT020SG
Manufacturer:
Zilog
Quantity:
10 000
Z8 Encore! XP
The errata listed in
0344 to 0519, where the date code is YYWW (year and week of assembly). Date codes 0442 to 0519 are
mixed; the errata will apply to some units, but not others. These errata are NOT APPLICABLE to date
codes 0520 and later. When reviewing the following errata, it is recommended that you also download the
most recent version of the Product Specification.
Table 1. Z8 Encore! XP F64XX Series Errata Date Code 0344 to 0519
Sl
No. Summary
1
2
3
Read protect (RP)
option bit may be
bypassed.
START, STOP and
NAK bits in the I
control register can
be cleared by soft-
ware writing a 0 to
these bits.
Device may not com-
plete Stop Mode
Recovery initiated by
a general-purpose
input/output (GPIO)
pin transition.
Table 1
®
2
C
F64XX Series with Date Codes 0344 to 0519
UP006010-0508
are found in Zilog’s Z8 Encore! XP
Description
The RP option bit does not prevent Flash access when bypassing the Flash
controller. For more information, refer to Third Party Flash Programming Sup-
port for Z8 Encore!
User code cannot be read through the on-chip debugger when read protect is
enabled. User code can only be read out when bypassing the Flash controller.
Workaround
None
The START, STOP, and NAK bits in the I
software writing a 0 to these bits. The Product Specification states that they
cannot be cleared by writing a 0.
Workaround
None
When Stop Mode Recovery is initiated by a GPIO pin transition, multiple pin
transitions within 200 μs (approximate) of each other may cause the device to
only partially wake up from STOP mode. Therefore, the device idles in a state
between STOP mode and normal operation. The crystal oscillator is oscillat-
ing, but code does not execute.
When stuck in this idle state, assertion of the external RESET pin does not ini-
tiate a system reset.
Workaround
The workarounds are listed below:
Copyright ©2008 by Zilog
Add external filtering to the Stop Mode Recovery pin input signal to pre-
vent multiple transitions in less than 200 μs.
Enable the Watchdog Timer (WDT) in STOP mode to allow a WDT to
complete the Stop Mode Recovery in the event the device does not suc-
cessfully complete the Stop Mode Recovery initiated by the GPIO pin tran-
sition.
www.zilog.com
®
MCU Application Note (AN0117).
Product Update
Errata for Z8 Encore! XP
F64XX Series
®
, Inc. All rights reserved.
®
F64XX Series devices with date codes
2
C control register can be cleared by
®

Related parts for Z8F4823FT020SG

Z8F4823FT020SG Summary of contents

Page 1

... The errata listed in Table 1 are found in Zilog’s Z8 Encore! XP 0344 to 0519, where the date code is YYWW (year and week of assembly). Date codes 0442 to 0519 are mixed; the errata will apply to some units, but not others. These errata are NOT APPLICABLE to date codes 0520 and later ...

Page 2

Z8 Encore! XP F64XX Series with Date Codes Prior to 0344 The errata listed in Table 2 are found in the production Z8 Encore! XP codes prior to 0344, where the date code is YYWW (year and week of ...

Page 3

Table 2. Z8 Encore! XP F64XX Series Errata Date Coded Prior to 0334 (Continued) Sl No. Summary Description 4 UART address com- Setting bit 7 (MPMD[1]) of the UART control 1 register to 1 does not produce pare function does ...

Page 4

Table 2. Z8 Encore! XP F64XX Series Errata Date Coded Prior to 0334 (Continued) Sl No. Summary Description 11 RESET pin is not fil- The RESET pin does not properly filter the input signal. The device may enter tered. Reset ...

Page 5

... TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within this document has been verified according to the general principles of electrical and mechanical engineering. Z8, Z8 Encore!, and Z8 Encore! XP are registered trademarks of Zilog, Inc. All other product or service names are the property of their respective owners. ...

Related keywords