C8051F041-GQR Silicon Laboratories Inc, C8051F041-GQR Datasheet - Page 168

no-image

C8051F041-GQR

Manufacturer Part Number
C8051F041-GQR
Description
IC 8051 MCU 64K FLASH 64TQFP
Manufacturer
Silicon Laboratories Inc
Series
C8051F04xr
Datasheets

Specifications of C8051F041-GQR

Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
CAN, EBI/EMI, SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
32
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4.25K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x8b, 13x12b; D/A 2x10b, 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TQFP, 64-VQFP
For Use With
336-1205 - DEV KIT FOR F040/F041/F042/F043
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F041-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F041-GQR
0
C8051F040/1/2/3/4/5/6/7
13.7.1. Enable/Reset WDT
The watchdog timer is both enabled and reset by writing 0xA5 to the WDTCN register. The user's applica-
tion software should include periodic writes of 0xA5 to WDTCN as needed to prevent a watchdog timer
overflow. The WDT is enabled and reset as a result of any system reset.
13.7.2. Disable WDT
Writing 0xDE followed by 0xAD to the WDTCN register disables the WDT. The following code segment
illustrates disabling the WDT:
The writes of 0xDE and 0xAD must occur within 4 clock cycles of each other, or the disable operation is
ignored. Interrupts should be disabled during this procedure to avoid delay between the two writes.
13.7.3. Disable WDT Lockout
Writing 0xFF to WDTCN locks out the disable feature. Once locked out, the disable operation is ignored
until the next system reset. Writing 0xFF does not enable or reset the watchdog timer. Applications always
intending to use the watchdog should write 0xFF to WDTCN in the initialization code.
13.7.4. Setting WDT Interval
WDTCN.[2:0] control the watchdog timeout interval. The interval is given by the following equation:
For a 3 MHz system clock, this provides an interval range of 0.021 ms to 349.5 ms. WDTCN.7 must be
logic 0 when setting this interval. Reading WDTCN returns the programmed interval. WDTCN.[2:0] reads
111b after a system reset.
168
4
3
CLR
MOV
MOV
SETB
+
WDTCN 2 0
EA
WDTCN,#0DEh
WDTCN,#0ADh
EA
T
sysclk
; disable all interrupts
; disable software watchdog timer
; re-enable interrupts
; where T
sysclk
is the system clock period.
Rev. 1.5