SAF-XC167CI-16F20F BB Infineon Technologies, SAF-XC167CI-16F20F BB Datasheet - Page 68

no-image

SAF-XC167CI-16F20F BB

Manufacturer Part Number
SAF-XC167CI-16F20F BB
Description
IC MCU 16BIT 128KB TQFP-144-19
Manufacturer
Infineon Technologies
Series
XC16xr
Datasheet

Specifications of SAF-XC167CI-16F20F BB

Core Processor
C166SV2
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, EBI/EMI, I²C, SPI, UART/USART
Peripherals
PWM, WDT
Number Of I /o
103
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.35 V ~ 2.7 V
Data Converters
A/D 16x8/10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-LFQFP
For Use With
B158-H8963-X-X-7600IN - KIT EASY XC167CIMCBX167-NET - BOARD EVAL INFINEON CAN/ETHRNTMCBXC167-BASIC - BOARD EVAL BASIC INFINEON XC16X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Other names
FX167CI16F20FBBNP
FX167CI16F20FBBXP
SAFXC167CI16F20FBB
SP000094528
SP000224688
3) The limit values for
4) This parameter includes the sample time
5) The actual duration of the reset calibration depends on the noise on the reference signal. Conversions
6) Not subject to production test - verified by design/characterization.
Figure 14
Data Sheet
result register with the conversion result (
Values for the basic clock
When the post-calibration is switched off, the conversion time is reduced by 12 ×
executed during the reset calibration increase the calibration time. The TUE for those conversions may be
increased.
The given parameter values cover the complete operating range. Under relaxed operating conditions
(temperature, supply voltage) reduced values can be used for calculations. At room temperature and nominal
supply voltage the following typical values can be used:
C
AINTtyp
V
= 12 pF,
AIN
Equivalent Circuitry for Analog Inputs
C
AINStyp
f
BC
R
must not be exceeded when selecting the peripheral frequency and the ADCTC setting.
Source
= 7 pF,
t
BC
depend on programming and can be taken from
R
AINtyp
C
= 1.5 kΩ,
Ext
t
t
S
SYS
, the time for determining the digital result and the time to load the
= 1/
C
f
SYS
AREFTtyp
66
).
C
= 15 pF,
AINT
R
AIN, On
-
C
C
AINS
AREFStyp
= 13 pF,
A/D Converter
Table
Electrical Parameters
t
BC
.
15.
R
MCS05570
C
AREFtyp
XC167CI-16F
AINS
Derivatives
V1.3, 2006-08
= 0.7 kΩ.

Related parts for SAF-XC167CI-16F20F BB